Pressure Relief Procedure 
8
310824D
Pressure Relief Procedure
1.
Turn OFF power and turn pressure control to lowest 
pressure setting.
2.
Hold gun against side of grounded metal flushing 
pail. Trigger gun to relieve pressure.
3.
Turn prime valve down.
If you suspect the spray tip or hose is clogged or that 
pressure has not been fully relieved after following the 
steps above, VERY SLOWLY loosen tip guard retaining 
nut or hose end coupling to relieve pressure gradually, 
then loosen completely. Clear hose or tip obstruction.
4.
Engage trigger safety lock on gun if unit is being 
shut down or left unattended.
WARNING
Follow this Pressure Relief Procedure whenever you 
are instructed to relieve pressure, stop spraying, check 
or service equipment or install or clean spray tip. Read 
Injection Hazard Warning, page 3.
FLUSH
ti5310a
ti5304a