Figure 1-2 shows the basic organization format of the AT command line. 
Figure 1-2  Basic organization format the AT command line 
ATCMD1 CMD2=12; +CMD1; +CMD2=,,15; +CMD2?; +CMD2=?<CR>
command line prefix
basic command
(no + prefix)
subparameter
extended command
(prefixed with +)
extended commands are
delimited with semicolon
subparameters
may be omitted
command line
termination character
read command for checking
current subparameter values
test command for checking
possible subparameter values
 
 
The returned value of the AT command consists of two parts: response message and 
result codes. Figure 1-3 shows an example of returned value of the AT command. 
Figure 1-3  An example of returned value of the AT command 
<CR><LF>+CMD2: 3,0,15,"GSM"<CR><LF>
<CR><LF>+CMD2: (0-3),(0,1),(0-12,15),("GSM","IRA")<CR><LF>
<CR><LF>OK<CR><LF>
information response to +CMD2?
information response to +CMD2=?
final result code
also string type subparameters possible
shows acceptable ranges of each subparameter
 
 
1.4.2 Types of AT Commands 
AT commands are categorized into three types: basic commands, S register 
commands, and extended and vendor-defined commands. 
A basic command starts with a single letter or with the & symbol plus a single letter. 