3com 980-000077/002 Manual De Usuario

Descargar
Página de 78
5-4
C
HAPTER
 5: N
OVELL
 IPX R
OUTING
Configure the Ethernet Port
A unique port IP address and the network subnet mask are required 
for the Ethernet port (for management of the unit), even if the 
network is always entirely connected within a non-IP Netware 
environment.
Enter 
CO
 
PO
 to display the Port Configuration screen. 
Select the 
LAN1
 port using the Arrow keys and enter 
ED
 to display 
the Edit Ethernet Port screen.
Type a valid, unique IP address for the unit in the Port IP Address 
field. Do not type the local network IP address.
Type a valid subnet mask for the network in the Port IP Mask field.
Type the IPX network number for the LAN on which the unit is sited 
in the Port IPX Network field.
Toggle the setting of the IPX Frame Type field, using the Spacebar, to 
the correct frame type for the network.
The frame type must be correct for the network environment in which 
the unit is operating. If the frame type is not correct, the unit will not 
pass data. Contact the network administrator for more information 
about the frame type used.
Press [Ctrl]+[E] to submit the new setting and then enter 
SAVE
Configure the ISDN Network Type
The ISDN network type parameter must be set to the correct ISDN 
service, otherwise connections and data transmission over dial-up 
ISDN links will not be possible. In the U.S.A., an additional customer 
identification number, known as a Service Provider Identification 
Number
 (SPID) may be required.
Enter 
CO
 
IS
 
PA
 to display the ISDN Parameters screen.
Toggle the Network Type field, using the Spacebar, to the correct 
ISDN network type as given by the service provider.
Press [Ctrl]+[E] to submit the new setting and then enter 
SAVE
Get_con.bk : IPX_ROUT.FRM  Page 4  Friday, October 3, 1997  1:49 PM