3com 980-000077/002 Manual De Usuario

Descargar
Página de 78
5-12
C
HAPTER
 5: N
OVELL
 IPX R
OUTING
Enter 
PASSWORD
 (in upper-case letters) when the Enter Password 
screen is displayed.
Configuring the Remote Unit
Changing the IP address during the remote management session will 
cause the session to be disconnected when the new address is 
submitted. This is normal. 
Assign the Unit Name
The unit must be assigned a unique name. The unit software relies 
on associating unit names with ISDN numbers for its core 
functionality.
Enter 
CO
 
SYS
 to display the System Parameters screen. 
Type in the name assigned to this remote unit in the Unit Name field. 
The name must be exactly the same as that used when configuring the 
central site unit ISDN Numbers table. 
Unit names are case-sensitive and must be entered correctly.
Press [Ctrl]+[E] to submit the new setting and then enter 
SAVE
Configure the Ethernet Port
A unique port IP address and the network subnet mask are required 
for the Ethernet port (for management of the unit), even if the 
network is always entirely connected within a non-IP Netware 
environment.
Enter 
CO
 
PO
 to display the Port Configuration screen. 
Select the 
LAN1
 port using the Arrow keys and enter 
ED
 to display 
the Edit Ethernet Port screen.
Type a valid, unique IP address for the unit in the Port IP Address 
field. Do not type the local network IP address.
Type a valid subnet mask for the network in the Port IP Mask field.
Type the IPX network number in the Port IPX Network field. 
Toggle the setting of the IPX Frame Type field, using the Spacebar, to 
the correct frame type for the network.
Get_con.bk : IPX_ROUT.FRM  Page 12  Friday, October 3, 1997  1:49 PM