Toshiba TIC-LF494B Manual De Usuario

Descargar
Página de 16
  
TIC-LF494B 
Field Intelligent Device Series 
Sanitary Electromagnetic Flowmeter 
  
Introduction 
Sanitary electromagnetic flowmeters LF490 series are 
designed for applications handling food and beverages. 
Sanitary flowmeters must be structured in such a way 
that operation and handling is simple, easy and 
thorough for the purpose of sanitary control such as 
cleaning (CIP/SIP), sterilization and drying. The 
sanitary flowmeter has features provided with normal 
electromagnetic flowmeters and by using sanitary 
fittings for pipeline connections fluid does not remain 
in any place along the detector pipeline. Therefore, it is 
fit for flowrate measurement for food and beverages. 
The electromagnetic flowmeter uses Faraday’s Law of 
electromagnetic induction to measure the process flow. 
The device consists of two units: a detector, through 
which the fluid to be measured flows and in which 
low-level signals proportional to flow rates are 
obtained; and a converter, which supplies excitation 
current to the detector, and amplifies the signals from 
the detector and then processes and converts the 
signals into the 4–20mAdc current signal or 
communication signal. With the unique patented 
Mount-Anywhere magnetic field distribution 
technology, the meter is highly immune to upstream 
flow disturbances. Combined with a multi-functional 
converter LF610 (combined type) or LF612 (separate 
type) equipped with its patented Noise-Sentry original 
noise-suppression circuit and advanced algorithms. 
The LF490 has a very high tolerance to noise, giving 
the unit a very stable output even for slurry fluid 
measurement. IR (Infrared) switches enable parameter 
setting of the converter without removing the cover. 
Flow direction can be set in either way, and its unique 
128 x 128 dot matrix LCD  display allows the LCD to 
be rotated electronically to 90, 180 and 270 degrees 
without opening the cover. 
 
 
 
 
 
 
 
 
  
 
 
Figure2.  LF490 series flowmeters 
 
 
 
 
 
 
 
 
 
The AF900 hand-held terminal (HART*
communicator) can be used to communicate with the 
flowmeter from a remote place. PROFIBUS-PA*
 
interface is available as an option. 
*1: HART protocol (Highway Addressable Remote 
Transducer) is a communication protocol for industrial 
sensors recommended by the HCF
 
(HART
 
Communication
 
Foundation). 
*2: PROFIBUS is the communication protocol for factory 
and process automation that the PROFIBUS 
Organization recommends. Instead of analog control 
with a conventional analog signal (4-20mA), it is the 
fieldbus which digitizes all signals. Flowmeters support 
PROFIBUS-PA. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
LF494/LF610 
LF494/LF612 
1S to 4S (25 to 100 mm) 
  
   
Certification 
number
 
Z01207
 
 
   
Power supply 
Converter 
I/O 
Detector 
 
Power  
supply 
I/O
Detector 
Terminal box 
Signal cable 
Excitation cable
Converter 
LF490/LF610 
LF494/LF610F 
LF490 
LF494 
LF612 
LF612F 
Combined type 
LF490/LF610 
LF494/LF610F 
Separate type
LF490/LF612 
LF494/LF612F 
Figure1.  Configuration