CONNECTING TO THE NETWORK
EMM-E6 User’s Guide
3-25
3.9.4
Connecting a Thin-Net Segment to an EPIM-C
To connect a thin-net segment to an EPIM-C:
1.
Set the Internal Termination Switch (Figure 3-14), located above the 
port (when the EPIM has been inserted into the EMM-E6) and 
labeled TERM to:
• the ON position (
) to internally terminate the thin-net segment at 
the port.
• the OFF position (
) if you do not want the thin-net segment to 
internally terminate at the port.
2.
If the Internal Termination Switch is in the On position, connect the 
thin-net segment directly to the BNC port.
3.
If the Internal Termination switch is in the Off position:
a.
Attach a BNC T-connector to the BNC port on the module.
b. Attach the thin-net segment to one (1) of the female connectors on 
the T-connector.
c. Attach another thin-coaxial segment or a terminator to the other 
female connector on the T-connector.
Failure to terminate each T-connector segment may result in 
improper segment operation. Place a terminator on any open 
female connection on the T-connector.
!
CAUTION
Connecting a thin-net segment to earth ground at more than 
one point could produce dangerous ground currents.