TPS-12G/15G/17G-QM Troubleshooting (Continued) 
TROUBLE 
POSSIBLE 
CAUSE(S) 
CORRECTIVE ACTION 
Wrong VisionTools 
Pro-e or SIMPL 
Windows
 
programs. 
Verify correct programs. 
Verify proper video set 
up. 
No video displayed. 
Incorrect input 
connection. 
Verify video input and QM 
connections. 
TPS-12G/15G/17G-QM 
does not respond to 
ping command. 
IP address not correct 
(LAN green and amber 
LEDs are off). 
Assign correct IP address 
to  
TPS-12G/15G/17G-QM. 
 
IP mask not correct 
(LAN green and amber 
LEDs are on). 
Assign correct IP mask. 
 
The PC and the  
TPS-12G/15G/17G-QM 
are not on same 
subnet. 
Ensure that the PC and 
the  
TPS-12G/15G/17G-QM 
are on the same subnet. 
Mouse or touchpanel 
does not work. 
Incorrect Touch 
settings. 
Check Touch settings on 
INTERFACE MENU. 
Touchpanel does not 
communicate with 
RS-232 devices. 
Incorrect RS-232 
settings. 
Match communication 
settings of touchpanel to 
peripheral device. 
Touchpanel display is 
dark. 
Standby timeout has 
elapsed. 
Touch the screen to 
reactivate. 
Unexpected response 
from the touchpanel. 
Touchpanel is 
incorrectly calibrated. 
Enter “SETUP MODE” 
and recalibrate. 
Improper Ethernet 
connection (IEC).  
Another device set to 
the same IP address. 
Obtain new touchpanel 
static IP address. 
Check Network Wiring 
Use the Right Wire 
In order to ensure optimum performance over the full range of your installation 
topology, Crestron Certified Wire and only Crestron Certified Wire may be used. 
Failure to do so may incur additional charges if support is required to identify 
performance deficiencies because of using improper wire. 
Calculate Power 
CAUTION:  Use only Crestron power supplies for Crestron equipment. Failure to 
do so could cause equipment damage or void the Crestron warranty. 
CAUTION:  Provide sufficient power to the system. Insufficient power can lead to 
unpredictable results or damage to the equipment. Please use the Crestron Power 
Calculator to help calculate how much power is needed for the system 
(
)
When calculating the length of wire for a particular Cresnet run, the wire gauge and 
the Cresnet power usage of each network unit to be connected must be taken into 
consideration. Use Crestron Certified Wire only. If Cresnet units are to be daisy-
chained on the run, the Cresnet power usage of each network unit to be daisy-
chained must be added together to determine the Cresnet power usage of the entire 
60  
  Isys
®
 G-Series Touchpanels: TPS-12G/15G/17G-QM 
Operations Guide – DOC. 6415B 
Verify proper connection 
at touchpanel LAN port. 
Communications via 
the LAN port not 
functioning.