Maintenance
9
© Travis Industries
4070710
100-01194_000
Yearly Service Procedure
WARNING: Prior to removing the glass, shut off gas to the
appliance (or remove the batteries from the battery box and shut
off electricity to the fireplace).  This prevents any chance of
accidental burner ignition when accessing the firebox.
 
Failure to inspect and maintain the fireplace may lead to improper combustion and a potentially dangerous
situation.  We recommend the following procedures be done by a qualified technician.
1.  Remove the glass frame and log set (NOTE: the logs are very fragile - see page 11).  If severely
deteriorated,  replace.    Check  the  logs  for  sooting.  A small amount of soot along the bottom of the logs is
normal.  If excessive sooting  is  found,  the  fireplace  will  require  adjustment.    Contact  your  dealer.
2.  Inspect  the  burner  and  remove  any  debris.
 
Make sure the burner is not warped, cracked, or damaged.
 
Check the firebox and area around the pilot to make sure there is no warping or damage.
 
If  any  problem  is  found,  discontinue  use  and  contact  your  dealer  for  service.
3.  Replace the log set.  Clean and replace the glasss.  If the glass is damaged, replace.  Make sure the
gasket  along  the  perimeter  of  the  glass  contacts  the  face  of  the  firebox  and  forms  an  air-tight seal.  If it
does not, re-align or replace the gasket to insure an air-tight  seal.
4.  Start the burner.  The flames should be orange/yellow and not touch the top of the firebox.  If the pilot or
main  burners  do  not  burn  correctly,  contact  your  dealer  for  service.
5.  Remove any debris or vegetation near the vent termination.  Contact your dealer if any sooting  or
deterioration  is  found  near  the  vent  termination.