2.9 Power Failure Connections
Installation Manual
67
2.9
Power Failure Connections
2.9.1
Power Failure Connections
When the power supply to the PBX fails, power failure transfer will switch from the current connection 
to the Power Failure Connections.
Power Failure Connections connect a specific extension and an outside (CO) line in the event of 
power failure as follows:
Outside (CO) line 1—extension (T, R) jack 01
Outside (CO) line 4—extension (T, R) jack 09
Outside (CO) line 7—extension (T, R) jack 17
Notes
In the event of a power failure, system memory is protected by a factory-provided lithium 
battery. No system data will be lost, except for the Camp-on, Saved Number Redial, Last 
Number Redial, and Call Park data.
The current connection automatically switches to the Power Failure Connection when the 
power supply stops.
Proprietary telephones (PTs) cannot be used during a power failure. Therefore, we 
recommend connecting single line telephones (SLTs) in parallel with PTs to extension jacks 
01, 09, and 17.
As long as DC power is provided by the backup batteries, the PBX will remain fully 
operational and the connection will not switch to the Power Failure Connections.