Siemens A1 Manual De Usuario

Descargar
Página de 74
Real Applications 
International English 
44 
MICROMASTER  Applications Handbook 
7.5.4 
Key Parameter settings 
Table 7-5 
Key Parameters.  Material Handling Operation 
Number Value 
Meaning 
P1120 
0.3 
Ramp up  
P1121 
0.3 
Ramp down  
P0003 
003 
Allows all parameters to be adjusted and set. 
P1082 
100 
Maximum Output Frequency.  This wide speed range is possible 
because torque requirements are not excessive at high speed.   
P2000 
100 
Reference  Frequency. Used for analog, serial I/O etc. 0-10 V now 
corresponds to 0-100 Hz 
P0701 2 
Run 
left 
P0702 1 
Run 
right 
P0703 29 
External 
Trip 
P0731 
52.3 
Output Relay 1  Brake control.  Here the brake control operates 
immediately as P1216 and P1217 are set to 0. 
P1215 
Enable brake control function 
P1216 
Brake  release time 
P1217 
Brake  stop time 
P1310 
Continuous boost. In this application starting boost (P1312) proved 
more useful than continuous boost.  
P1312 100 
Starting 
boost 
P0300-
P0311 
*** 
Settings to suit motor