Real Applications 
International English 
42 
MICROMASTER  Applications Handbook 
7.4.4 
Key Parameter Settings 
Table 7-4 
Key Parameters.  Conveyor Application 
Number Value  Meaning 
P1120 
0.6 
Ramp up  
P1121 
0.6 
Ramp down. Fast ramping possible with these settings  
P1000 
003 
Fixed frequency operation  
P0003 
Allows all parameters to be adjusted and set. 
P1082 
110 
Maximum Output Frequency.  High speed operation possible in certain 
circumstances.   
P1060 
0.3 
Jog  (alternative) ramp up rate 
P1061 
0.3 
Jog  (alternative) ramp down rate  
P1001 
40 
Fixed frequency 1 
P1002 
45 
Fixed frequency 2 
P0701 
16 
Run at fixed frequency 1 
P0702 
16 
Run at fixed frequency 2 
P1124 
16722.2 
Use jog ramp times BiCo Function 
P0703 
99 
Enable BiCo function  
P0300-
P0311 
*** 
Settings to suit motor 
 
By setting P0701 and P0702  to 16, the drive starts and runs to the selected 