HP (Hewlett-Packard) 1660 Manual De Usuario
Set Up Level 1 of the State Trigger Specification
The first term you will look for and store before triggering is term "a", which
stores the value 011. Because you are only interested in 011, you will set the
"While Storing" field to "no state" so that no other data is stored.
stores the value 011. Because you are only interested in 011, you will set the
"While Storing" field to "no state" so that no other data is stored.
1
Highlight the
1
field in the State Sequence Levels box of the Trigger
menu. Press the
Select
key.
2
In the pop-up menu, highlight the field to the right of
While storing
, and
press the
Select
key. Highlight
no state
in the pop-up menu, and press
the
Select
key.
3
Highlight the field to the right of
Find
, and press the
Select
key.
Highlight
a
in the pop-up menu, and press the
Select
key.
4
Press the
Done
key to close the Sequence Level 1 pop-up menu.
Setting Up Level 1 of the State Trigger Specification
Result
Sequence Level 1 is set to find and store only term "a" the first time it occurs.
The analyzer will not
store any data before
it finds term "a".
store any data before
it finds term "a".
The "a" term holds
the decimal value
the decimal value
Advanced State Triggering
Set Up Level 1 of the State Trigger Specification
Set Up Level 1 of the State Trigger Specification
6-8