Set Up Level 1 of the State Trigger Specification
The first term you will look for and store before triggering is term "a", which
stores the value 011.  Because you are only interested in 011, you will set the
"While Storing" field to "no state" so that no other data is stored. 
1
Highlight the 
1
 field in the State Sequence Levels box of the Trigger
menu.  Press the 
Select
 key.
2
In the pop-up menu, highlight the field to the right of 
While storing
, and
press the 
Select
 key.  Highlight 
no state
 in the pop-up menu, and press
the 
Select
 key.
3
Highlight the field to the right of 
Find
, and press the 
Select
 key.
Highlight 
a
 in the pop-up menu, and press the 
Select
 key.
4
Press the 
Done
 key to close the Sequence Level 1 pop-up menu.
Setting Up Level 1 of the State Trigger Specification
Result
Sequence Level 1 is set to find and store only term "a" the first time it occurs.
The analyzer will not
store any data before
it finds term "a".
The "a" term holds
the decimal value
Advanced State Triggering
Set Up Level 1 of the State Trigger Specification
6-8