Setup Mode
312779E
37
Option Screen 2
External Color Change
If set to “Off”, Color/Catalyst Purge Time and Color/Cat-
alyst Fill Time appear in Advanced Setup Screen 1
page 39 or Recipe Setup Screen 2, page 44 (depend-
ing on whether Flush and Fill Inputs are set to “Global” 
or “Recipe”). 
If set to “On”, these fields are removed from the 
screens.
Auto Dump
If the auto dump feature is being used, set to “On”. Once 
the auto dump is enabled, the gun flush box is enabled 
and the potlife alarm is active for 2 minutes, the system 
will automatically flush out the old material.
Flow Rate Monitor
This field only appears if Flow Control is set to “Off” in 
Configure Screen 5, page 34
If set to “On,” Recipe Setup Screen 6 on page 46 is 
added, enabling setting of high and low flow limits.
If set to “Off,” flow rate monitoring is disabled and Rec-
ipe Setup Screen 6
 on page 46 will not appear.
Solvent Push Enable
To enable the Solvent Push feature, select “Solvent” or 
“3rd Valve” (available if 3rd Flush Valve in Configure 
Screen 3
, page 33, is set to “On”).
To disable the Solvent Push feature, set to “Off.” 
F