Setup Mode
312779E
39
NOTE: Each screen displays the current screen number 
and the total number of screens in the group. The total 
number of screens in a group and the fields displayed 
on each screen may vary depending on selections 
made in the System Configuration Screens and 
Option Screens
Advanced Setup Screen 1
Flow Control Override
This field only appears if Flow Control is set to “On” in 
Configure Screen 5 on page 34, and Manual Override 
is set to “On” (see below). The selections made will 
affect the display in Manual Override Screen on page 
25. Choose the desired selection as defined below:
Manual Override
This field only appears if Run Mode is set to “Automatic” 
or “Semi-automatic” in Configure Screen 3, page 33
Set to “On” to override all outside control. If selected, the 
Manual Override Screen (page 25) will be added, and 
the Flow Control Override field appears (see above).
Gun 1/Gun2 Potlife Volume
Enter the potlife volume (1 to 1999 cc) for each gun. 
This is the amount of material required to move through 
the mix manifold, hose and applicator/gun before the 
potlife timer is reset.
Use the following information to determine approximate 
pot life volume (PLV) in cc:
Integrator manifold and mixer volume = 75 cc
Spray Gun Volume = 20 cc
(Hose Volume* x Feet of Hose) + 75 + 20 = PLV
Color/Catalyst Purge
This field only appears if the system includes a color 
change module and Flush and Fill Input is set to 
“Global” in Option Screen 1, page 36. Enter the purge 
time (0 to 99 seconds). It refers to the amount of time 
required to flush the lines from the color or catalyst mod-
ule to the dose valve or dump valve.
Color/Catalyst Fill
This field only appears if the system includes a color 
change module and Flush and Fill Input is set to 
“Global” in Option Screen 1, page 36. Enter the fill time 
(0 to 99 seconds). It refers to the time required to fill the 
lines from the color or catalyst module to the dose valve 
or dump valve.
F
IG
. 40. Advanced Setup Screen 1
Selection
Description
Off
Normal operation
% Open
Flow control regulator is opened to a 
desired percentage.
Pressure
Flow control regulator is opened to a 
calibrated pressure.
F
IG
. 41. Flow Control Override Menu
Hose ID (inches)
Volume (cc/foot)*
3/16
5.43
1/4
9.648
3/8
21.71