Manual De UsuarioTabla de contenidosAbout this guide8Safety information7Chapter 1: Product introduction111.1 System package contents121.2 Serial number label121.3 System specifications131.4 Front panel features151.5 Rear panel features151.6 Internal features161.7 LED information171.7.1 Front panel LEDs171.7.2 LAN (RJ-45) LEDs171.7.3 HDD status LED18Chapter 2: Hardware setup192.1 Chassis cover202.2 Central Processing Unit (CPU)212.2.1 Installing the CPU212.2.2 Installing the CPU heatsink262.3 System memory272.3.1 Overview272.3.2 Memory Support List272.3.3 Memory Configurations292.3.4 Installing a DIMM on a single clip DIMM socket312.4 Hard disk drives322.5 Expansion slot342.5.1 Installing an expansion card to the riser card bracket342.5.2 Configuring an expansion card372.6 Cable connections382.7 SATAII/SAS backplane cabling392.8 Removable/optional components402.8.1 System fans402.8.2 Redundant power supply module412.8.3 Replacing optical drive (optional)422.8.4 Installing ASUS PIKE RAID card (optional)43Chapter 3: Installation options453.1 Friction Rail Kit Installation Guide463.1.1 Setting up the friction rail kit on the rack463.1.2 Mounting the server to the rack48Chapter 4: Motherboard information494.1 Motherboard layouts504.2 Jumpers524.3 Internal connectors564.4 Internal LEDs62Chapter 5: BIOS setup655.1 Managing and updating your BIOS665.1.1 ASUS CrashFree BIOS 3 utility665.1.2 ASUS EZ Flash 2 Utility675.1.3 BUPDATER utility685.2 BIOS setup program705.2.1 BIOS menu screen715.2.2 Menu bar715.2.3 Menu items725.2.4 Submenu items725.2.5 Navigation keys725.2.6 General help725.2.7 Configuration fields725.2.8 Pop-up window725.2.9 Scroll bar725.3 Main menu735.3.1 System Date [Day xx/xx/xxxx]735.3.2 System Time [xx:xx:xx]735.4 Advanced menu745.4.1 CPU Configuration745.4.2 CPU Power Management Configuration765.4.3 Chipset Configuration785.4.4 PCH SATA Configuration865.4.5 PCH SCU SAS Configuration875.4.6 PCI Subsystem Settings875.4.7 Onboard LAN Configuration935.4.8 USB Configuration945.4.9 Trusted Computing965.4.10 ACPI Settings975.4.11 WHEA Configuration985.4.12 APM985.4.13 Serial Port Console Redirection995.4.14 ME Subsystem1025.4.15 Legacy Devices Configuration1025.4.16 Runtime Error Logging1035.5 Server Mgmt menu1045.5.1 System Event Log1055.5.2 BMC network configuration1065.6 Event Logs menu1075.6.1 Change Smbios Event Log Settings1075.7 Boot menu1095.8 Monitor menu1125.9 Security menu1135.10 Tool menu1145.11 Exit menu115Chapter 6: RAID configuration1176.1 Setting up RAID1186.1.1 RAID definitions1186.1.2 Installing hard disk drives1186.1.3 RAID controller selection1196.1.4 Setting the RAID item in BIOS1196.2 LSI Software RAID Configuration Utility1206.2.1 Creating a RAID set1216.2.2 Adding or viewing a RAID configuration1276.2.3 Initializing the virtual drives1286.2.4 Rebuilding failed drives1326.2.5 Checking the drives for data consistency1346.2.6 Deleting a RAID configuration1376.2.7 Selecting the boot drive from a RAID set1386.2.8 Enabling WriteCache1396.3 Intel® Rapid Storage Technology enterprise SCU/SATA Option ROM Utility1406.3.1 Creating a RAID set1426.3.2 Creating a Recovery set1436.3.3 Deleting a RAID set1456.3.4 Resetting disks to Non-RAID1466.3.5 Exiting the Intel® Rapid Storage Technology utility1476.3.6 Rebuilding the RAID1476.3.7 Setting the Boot array in the BIOS Setup Utility1496.4 Intel® Rapid Storage Technology enterprise Utility (Windows)1506.4.1 Creating a RAID set1516.4.2 Change Volume Type1536.4.3 Delete volume1546.4.4 Preferences155Chapter 7: Driver installation1577.1 RAID driver installation1587.1.1 Creating a RAID driver disk1587.1.2 Installing the RAID controller driver1617.2 Intel® Chipset Device Software installation1707.3 Intel@ Network Connections Software installation1727.4 VGA driver installation1757.5 Intel® C600 Series Chipset SAS RAID (SATA mode) Drivers1787.6 Microsoft .NET Framework 3.5 SP11797.7 Intel® Rapid Storage Technology enterprise 3.0 installation1807.8 Intel® I350 Gigabit Adapters Driver installation1837.9 Management applications and utilities installation1877.9.1 Running the support DVD1877.9.2 Drivers menu1877.9.3 Utilities menu1887.9.4 Make disk menu1887.9.5 Contact information188Appendix: Reference information189Z9PP-D24 block diagram190Notices191ASUS contact information193Tamaño: 7 MBPáginas: 196Language: EnglishManuales abiertas
Manual De UsuarioTabla de contenidos给用户的说明2目录3使用注意事项7用电安全8关于本用户手册9第一章:系统导览131.1 产品包装内容141.2 序列号贴纸141.3 产品规格表151.4 前面板171.5 后面板171.6 内部组件181.7 LED 显示灯号说明191.7.1 前面板指示灯191.7.2 网络端口指示灯191.7.3 硬盘状态指示灯20第二章:硬件安装212.1 机箱上盖222.1.1 打开机箱后半部上盖222.2 中央处理器(CPU)232.2.1 安装中央处理器232.2.2 安装 CPU 散热片282.3 系统内存292.3.1 概述292.3.2 内存支持列表292.3.3 内存设置312.3.4 安装内存条332.3.5 取出内存条332.4 安装硬盘342.5 扩展插槽362.5.1 安装扩展卡至转接卡上362.5.2 设置扩展卡392.6 连接排线402.7 SATAII/SAS 背板排线的连接412.8 移除系统组件422.8.1 系统风扇422.8.2 备援式电源(PSU)模块432.8.3 薄型光驱(选购)442.8.4 安装华硕 PIKE RAID 控制卡(选购)45第三章:高级安装473.1 安装标准滑轨套件483.1.1 安装标准滑轨套件至服务器上483.1.2 安装服务器至机架上50第四章:主板信息514.1 主板结构图524.2 跳线选择区544.3 元件与外围设备的连接584.4 内部指示灯64第五章:BIOS 程序设置675.1 管理、升级您的 BIOS 程序685.1.1 华硕 CrashFree BIOS 3 程序685.1.2 使用华硕 EZ Flash 2 升级程序695.1.3 BUPDATER 工具程序705.2 BIOS 程序设置725.2.1 BIOS 程序菜单介绍735.2.2 功能表列说明735.2.3 菜单项目745.2.4 子菜单745.2.5 操作功能键说明745.2.6 在线操作说明745.2.7 设置值745.2.8 设置窗口745.2.9 滚动条745.3 主菜单(Main)755.3.1 System Date [Day xx/xx/xxxx]755.3.2 System Time [xx:xx:xx]755.4 高级菜单(Advanced menu)765.4.1 处理器设置(CPU Configuration)765.4.2 CPU 电源管理设置785.4.3 芯片组设置(Chipset Configuration)805.4.4 PCH SATA 设置(PCH SATA Configuration)865.4.5 PCI 子系统设置(PCI Subsystem Settings)875.4.6 Intel TXT(LT-SX) 设置905.4.7 内置网络设置(Onboard LAN Configuration)915.4.8 USB 设置(USB Configuration)925.4.9 Trusted Computing945.4.10 ACPI 设置955.4.11 WHEA 设置965.4.12 APM 设置965.4.13 串口控制面板重新定向975.4.14 ME 子系统(ME Subsystem)1005.4.15 既有设备设置(Legacy Devices Configuration)1005.4.16 运行时错误记录(Runtime Error Logging)1015.5 服务器管理菜单(Server Mgmt menu)1025.5.1 系统事件记录(System Event Log)1035.5.2 BMC 网络设置(BMC network configuration)1045.6 事件记录菜单(Event Logs menu)1055.6.1 更改 Smbios 事件记录设置1055.7 启动菜单(Boot menu)1075.8 监控菜单(Monitor menu)1095.9 安全性菜单(Security menu)1105.10 工具菜单(Tool menu)1115.11 退出 BIOS 程序(Exit)112第六章:磁盘数组设置1136.1 RAID 功能设置1146.1.1 RAID 功能说明1146.1.2 硬盘安装1156.1.3 RAID 设置程序选择1156.1.4 设置 RAID BIOS 选项1156.2 LSI Software RAID 设置程序1166.2.1 创建 RAID 设置1176.2.2 增加或查看一个 RAID 设置1236.2.3 将虚拟磁盘初始化1246.2.4 重新创建损坏的硬盘1286.2.5 检查硬盘数据的一致性1306.2.6 删除一个 RAID 设置1336.2.7 从 RAID 设置中选择启动磁盘1346.2.8 开启 WriteCache1356.3 Intel® Rapid Storage Technology enterprise SATA Option ROM 工具程序1366.3.1 创建 RAID 设置1376.3.2 创建一个恢复设置1386.3.3 删除 RAID 磁区1406.3.4 重新设置硬盘为非数组硬盘1416.3.5 退出 Intel Matrix Storage Manager 程序1426.3.6 修复 RAID 磁盘数组1426.3.7 在 BIOS 程序中设置启动数组1446.4 Intel® Rapid Storage Technology enterprise 工具程序(Windows)1456.4.1 创建 RAID 阵列1466.4.2 更改卷类型1486.4.3 删除卷1496.4.4 偏好设置150第七章:安装驱动程序1517.1 安装 RAID 驱动程序1527.1.1 创建一张 RAID 驱动软盘1527.1.2 安装 RAID 驱动程序1557.2 安装 Intel® 芯片驱动程序1647.3 安装 Intel® Network Connection 软件1667.4 安装显示驱动程序1697.5 安装 Intel® C600 系列芯片 SCU SATA RAID 驱动程序1727.6 安装 Microsoft .NET Framework 3.5 SP1 软件1737.7 安装 Intel® Rapid Storage Technology enterprise 3.0 程序1747.8 安装 Intel® I350 Gigabit 网络驱动程序1777.9 安装管理工具与应用程序1817.9.1 运行公用与驱动程序光盘1817.9.2 驱动程序主菜单1817.9.3 工具软件菜单1827.9.4 制作驱动程序软盘菜单1827.9.5 联络信息182附录183A.1 Z9PP-D24 结构图184Tamaño: 10 MBPáginas: 188Language: 中文(zhōngwén)Manuales abiertas
Manual De UsuarioTabla de contenidos給使用者的說明2目錄3使用注意事項7用電安全8關於本使用手冊9第一章:系統導覽111.1 產品包裝內容121.2 序號貼紙121.3 產品規格表131.4 前端面板151.5 後端面板151.6 內部組件161.7 LED 顯示燈號說明171.7.1 前面板指示燈171.7.2 網路埠指示燈171.7.3 硬碟狀態指示燈18第二章:硬體安裝192.1 機殼上蓋202.1.1 打開機殼後半部上蓋202.2 中央處理器(CPU)212.2.1 安裝中央處理器212.2.2 安裝 CPU 散熱片262.3 系統記憶體272.3.1 概觀272.3.2 記憶體支援列表272.3.3 記憶體設定292.3.4 安裝記憶體模組312.3.5 取出記憶體模組312.4 安裝硬碟機322.5 擴充插槽342.5.1 安裝擴充卡至轉接卡上342.5.2 設定擴充卡372.6 連接排線382.7 SATAII/SAS 背板排線的連接392.8 移除系統組件402.8.1 系統風扇402.8.2 備援式電源供應器模組412.8.3 薄型光碟機(選購)422.8.4 安裝華碩 PIKE RAID 控制卡(選購)43第三章:進階安裝453.1 安裝標準滑軌套件463.1.1 安裝標準滑軌套件至伺服器上463.1.2 安裝伺服器至機架上48第四章:主機板資訊494.1 主機板構造圖504.2 跳線選擇區524.3 元件與周邊裝置的連接564.4 內部指示燈62第五章:BIOS 程式設定655.1 管理、更新您的 BIOS 程式665.1.1 華碩 CrashFree BIOS 3 程式665.1.2 使用華碩 EZ Flash 2 更新程式675.1.3 BUPDATER 工具程式685.2 BIOS 程式設定705.2.1 BIOS 程式選單介紹715.2.2 功能表列說明715.2.3 選單項目725.2.4 子選單725.2.5 操作功能鍵說明725.2.6 線上操作說明725.2.7 設定值725.2.8 設定視窗725.2.9 捲軸725.3 主選單(Main)735.3.1 System Date [Day xx/xx/xxxx]735.3.2 System Time [xx:xx:xx]735.4 進階選單(Advanced menu)745.4.1 處理器設定(CPU Configuration)745.4.2 CPU 電源管理設定765.4.3 晶片組設定(Chipset Configuration)785.4.4 PCH SATA 設定(PCH SATA Configuration)845.4.5 PCI 子系統設定(PCI Subsystem Settings)855.4.6 Intel TXT(LT-SX) 設定885.4.7 內建網路設定(Onboard LAN Configuration)895.4.8 USB 設定(USB Configuration)905.4.9 Trusted Computing925.4.10 ACPI 設定935.4.11 WHEA 設定945.4.12 APM 設定945.4.13 序列埠控制面板重新定向(Serial Port Console Redirection)955.4.14 ME 子系統(ME Subsystem)985.4.15 既有裝置設定(Legacy Devices Configuration)985.4.16 執行時錯誤記錄(Runtime Error Logging)995.5 伺服器管理選單(Server Mgmt menu)1005.5.1 系統事件記錄(System Event Log)1015.5.2 BMC 網路設定(BMC network configuration)1025.6 事件記錄選單(Event Logs menu)1035.6.1 變更 Smbios 事件記錄設定(Change Smbios Event Log Settings)1035.7 開機選單(Boot menu)1055.8 監控選單(Monitor menu)1075.9 安全性選單(Security menu)1085.10 工具選單(Tool menu)1095.11 離開 BIOS 程式(Exit)110第六章:磁碟陣列設定1116.1 RAID 功能設定1126.1.1 RAID 功能說明1126.1.2 硬碟安裝1136.1.3 RAID 設定程式選擇1136.1.4 設定 RAID BIOS 選項1136.2 LSI Software RAID 設定程式1146.2.1 建立 RAID 設定1156.2.2 增加或檢視一個 RAID 設定1216.2.3 將虛擬磁碟初始化1226.2.4 重新建立損壞的硬碟1266.2.5 檢查硬碟資料的一致性1286.2.6 刪除一個 RAID 設定1316.2.7 從 RAID 設定中選擇開機磁碟1326.2.8 開啟 WriteCache1336.3 Intel® Rapid Storage Technology enterprise SATA Option ROM 工具程式1346.3.1 建立 RAID 設定1356.3.2 建立一個回復設定1366.3.3 刪除 RAID 磁區1386.3.4 重新設定硬碟為非陣列硬碟1396.3.5 退出 Intel Matrix Storage Manager 程式1406.3.6 重建 RAID 設定1406.3.7 在 BIOS 程式中設定開機陣列1426.4 Intel® Rapid Storage Technology enterprise 工具程式(Windows)1436.4.1 建立 RAID 陣列1446.4.2 變更 Volume 類型1466.4.3 刪除 volume1476.4.4 偏好選項(Preferences)148第七章:安裝驅動程式1497.1 安裝 RAID 驅動程式1507.1.1 建立一張 RAID 驅動磁片1507.1.2 安裝 RAID 驅動程式1537.2 安裝 Intel® 晶片驅動程式1627.3 安裝 Intel® Network Connection 軟體1647.4 安裝顯示驅動程式1677.5 安裝 Intel® C600 系列晶片 SCU SATA RAID 驅動程式1707.6 安裝 Microsoft .NET Framework 3.5 SP1 軟體1717.7 安裝 Intel® Rapid Storage Technology enterprise 3.0 程式1727.8 安裝 Intel® I350 Gigabit 網路驅動程式1757.9 安裝管理工具與應用程式1797.9.1 執行公用與驅動程式光碟1797.9.2 驅動程式主選單1797.9.3 工具軟體選單1807.9.4 製作驅動程式磁片選單1807.9.5 聯絡資訊180附錄181A.1 Z9PP-D24 架構圖182Tamaño: 10 MBPáginas: 186Language: 中文(zhōngwén)Manuales abiertas