Viewing Continuous mode measurement data
To view basic data from Continuous mode measurement, use the Quick View menu shown in 
Figure 5-3. Process variables available from the Quick View menu are listed in Table 5-6.
Note: You can also read Continuous mode measurement data via Modbus or report actual and 
average process variables by assigning them to a milliamp or frequency output.
To view more detailed data, use the View Production Measurement menu shown in Figure 5-3. This 
screen provides:
Production data for several other process variables, as listed in Table 5-7
TMR data, as listed in Table 5-8
Table 5-6
Quick View data – Continuous mode
Process variable
Definition
Average net oil rate
Average net oil flow rate, calculated from the beginning of Continuous mode measurement or 
from the last reset. May or may not include oil carry-over, depending on TMR configuration.
Net oil total
Total net oil, by volume, calculated from the beginning of Continuous mode measurement or 
from the last reset. May or may not include oil carry-over, depending on TMR configuration.
Average water cut
Average water cut value, calculated from the beginning of Continuous mode measurement or 
from the last reset. May be either density-based or from the water cut monitor, depending on 
water cut configuration.
Average gross rate
Average flow rate of production fluid, calculated from the beginning of Continuous mode 
measurement or from the last reset. May or may not include TMR carry-over data, depending 
on TMR configuration. Does not include gas data.
Gross total
Total production fluid, by volume, calculated from the beginning of Continuous mode 
measurement or from the last reset. May or may May or may not include TMR carry-over data, 
depending on TMR configuration. Does not include gas data.
Average/total since
Timestamp of beginning of Continuous mode measurement or the last Reset All.
Test time elapsed
Hours and minutes since this Continuous mode measurement period was started
Transient bubble time
Hours and minutes that TBR has been active
Water cut overrange
(Water cut monitor only) Hours and minutes that the water cut has been above the configured 
External Water Cut Limit
Total paused time
Hours and minutes that measurement has been paused
Transient mist time
Hours and minutes that TMR has been active