Emerson MMI-20011276 Manuel D’Utilisation

Page de 78
52
Micro Motion
®
 Series 3000 MVD Transmitters
Operation Mode – NOC
5.3.2
Pausing and resuming Continuous mode measurement
Use the Pause / Resume option shown in Figure 5-3 to pause and resume Continuous mode 
measurement. While measurement is paused, no data is collected, displayed, or stored, and average, 
minimum, maximum, total, or inventory values are not updated.
You can pause and resume measurement as often as you wish. 
Table 5-7
Production data accessible via View Production Measurement screen – Continuous mode
Process variable
Values
Actual Avg
Min
Min 
time/ 
date
Max
Max 
time/ 
date
Total 
Reset 
time/ 
date
Inventory
Net  oil
Y
Y
Y
Y
Y
Y
Y
Y
Y
Water  cut
Y
Y
Y
Y
Y
Y
Y
Gross  flow
Y
Y
Y
Y
Y
Y
Y
Y
Y
Net  water
Y
Y
Y
Y
Y
Y
Y
Y
Y
Drive gain
Y
Y
Y
Y
Y
Density
Y
Y
Y
Y
Y
Y
Y
Temperature
Y
Y
Y
Y
Y
Y
Y
Back  flow
Y
Y
Y
Y
Y
Y
Mass  flow
Y
Y
Y
Y
Y
Y
Y
Y
Y
TMR  drive  gain
Y
Y
Y
Y
Y
Y
Gas  volume
Y
Y
Y
Y
Y
Y
Y
Y
Y
Uncorrected flow
Uncorrected  oil
Y
Y
Y
Y
Y
Y
Y
Y
Y
Uncorrected  water
Y
Y
Y
Y
Y
Y
Y
Y
Y
Uncorrected water 
cut
Y
Y
Y
Y
Y
Y
Y
Uncorrected  gross
Y
Y
Y
Y
Y
Y
Y
Y
Y
Table 5-8
TMR data – Continuous mode
Process variable
Definition
Mass flow rate
Current mass flow rate from the gas meter
2-phase mass total
Total mass of liquid and gas in the gas stream during all TMR intervals
TMR mass total
Calculated mass of gas in the gas stream during all TMR intervals
Mass carry-over
Total mass of liquid in the gas stream during all TMR intervals (2-phase mass total minus TMR 
mass total)
Oil volume carry-over
Volume of oil in gas stream during all TMR intervals
Water volume carry-over
Volume of water in gas stream during all TMR intervals
Transient mist time
Hours and minutes that TMR has been active