Changing modes
Changing from Well Test mode to Continuous mode, or from Continuous mode to Well Test mode, 
affects current measurement and data collection. To change modes, follow the instructions in this 
section.
To change from Well Test mode to Continuous mode:
1. If a well test is running, it will be stopped automatically when the mode is changed.
2. Perform all required or desired recalculations.
3. Well test data will be unavailable from the display while the system is in Continuous mode. 
Record all required or desired well test data to an external system. 
4. Change 
Mode of Operation
 to 
Continuous Mode
.
To change from Continuous mode to Well Test mode:
1. If desired, save an archive record.
2. Perform all required or desired recalculations.
3. Continuous mode data will be unavailable from the display while the system is in Well Test 
mode. Record all required or desired data to an external system. 
4. Change 
Mode of Operation
 to 
Well Test Mode
.
Table 5-9
Recalculation parameters – Continuous mode measurement
Parameter
Configurable?
Definition
Original Ref Temp
(1)
(1) If the value was changed during the measurement period, the value displayed here is the value in use when the archive record was 
saved.
No
Reference temperature for NOC calculations applied during data 
collection
Recalc Reference Temp
Yes
Reference temperature to used for recalculation
Orig Water Density
No
Reference density of water applied during data collection
Recalc Water Density
Yes
Reference density of water to be used for recalculation
Original Oil Density
No
Reference density of oil applied during data collection
Recalc Oil Density
Yes
Reference density of oil to be used for recalculation
Original Press Comp Oil
No
Pressure compensation factor for oil applied during data collection
Recalc Press Comp Oil
Yes
Pressure compensation factor for oil to be used for recalculation
Original Ref Pressure
No
Reference pressure applied during data collection
Recalc Ref Pressure
Yes
Reference pressure applied to be used for recalculation
Original Gas Ref 
Density
No
Reference density of gas from this well applied during data collection
Recalc Gas Ref Dens
Yes
Reference density of gas to be used for recalculation
Original Factor for Oil
No
Shrinkage factor for oil applied during data collection
Recalc Factor for Oil
Yes
Shrinkage factor for oil to be used for recalculation
Original Factor for Water
No
Shrinkage factor for water applied during data collection
Recalc Factor for Water
Yes
Shrinkage factor for water to be used for recalculation