7  DSC/WATCH RECEIVER SETUP 
 7-5
ROUTINE
F1  :   2M-INTL
F2  :   2M-USR3
F3  :   4M-INTL
F4  :   8M-INTL
F5  : 16M-LCL1
F6  : 25M-LCL2
DISTRESS
  2M  :  
FIXED
  4M  :  ON
  6M  :  ON
  8M  :  
FIXED
12M  :  ON
16M  :  OFF
**
 Scan freq setup 
*
OFF
2 MHZ
4 MHZ
6 MHZ
8 MHZ
6
 
3.  Push the [ENTER] knob, and the display looks something like the one below. 
ROUTINE
F1  :   2M-INTL
F2  :   2M-USR3
F3  :   4M-INTL
F4  :   8M-INTL
F5  : 16M-LCL1
F6  : 25M-LCL2
DISTRESS
  2M  :  
FIXED
  4M  :  ON
  6M  :  ON
  8M  :  
FIXED
12M  :  ON
16M  :  OFF
**
 Scan freq setup 
*
INTL
: T2189.5/R 2177.0
DIST
: T 2187.5/R 2187.5
6
 
4.  Rotate the [ENTER] knob to choose frequency desired and then push the [ENTER] 
knob.  
INTL: International 
channels 
DIST: Distress 
channels 
 
LOCAL1/LOCAL2: Local 
channels 
USER CH: 
User channels 
5.  Press the [CANCEL] key twice to return to the DSC standby screen. 
 
Note: Distress frequencies can be stored on the routine frequency memory. This is 
convenient for backing up the watch keeping receiver. 