Cisco Systems 78-10588-03 Manuel D’Utilisation

Page de 30
Chapter 3
Installing the Chassis
Connecting Power
3-12
Cisco Metro 1500 Series Hardware Installation Guide
78-10588-03
Figure 3-5
Rear Panel of the PSM (US Version)
Caution
Do not use damaged terminal blocks. Immediately replace damaged
or defective terminal blocks
Step 3
Take a medium screwdriver and push it into the rectangular hole of the terminal
block. (See Figure 3-6.) At the same time, slide the insulation-free end of the wire
into the respective rectangular hole at the bottom of the power clamp. Repeat this
step for the other wires.
Instructions for
power supply
Fan module
    
Fuse 2   
    
Fuse 1  
    
March 1999
For continued protection against risk of fire replace
only with same type and ratings of fuse.
For proper selection of power supply cord refer to
instruction manual.
Always remove both poewr cords when
disconnecting from a power source.
Voltage:                       
Power Consumption
Fuse:                           2 
115/230 V 50/60 Hz
Max. Current:              2.5 A
    max. 100 W
x T 2,5 A / 250 V
Made in Germany
Always remove both 
power cords when dis-
connecting from power 
source !
!
Terminal blocks
Fuse
holders
Power 2   
    
Power 1