JVC GYHM150U Manuel D’Utilisation

Page de 104
69
* Default values are indicated in bold characters.
TC/UB Menu
Item
Setting Values
Function
For setting the operation of the time code.
Free Run
: The time code operates in the run mode at all times regardless of the recording 
status. It continues to run even when the power of the camera recorder is turned 
off.
: The time code operates in the run mode during recording. It continues to run in the 
order of the recorded clips as long as the SDHC/SDXC card is not replaced. If the 
SDHC/SDXC card is removed and recording is made on another card, time code 
will be recorded on the new card from where it was left off in the previous card.
: The time code operates in the run mode during recording. When the SDHC/SDXC 
card is replaced, the last time code recorded on the card is read and recorded on a 
new card so that the time code continues in running order. (
^
For setting the time code (hour, minute, second, frame).
Display
02:02:25.20
Non Drop setting 02:02:25:20
Memo :                                                                                                                                                                                                         
● When [TC Generator] is set to ARegenB, this item appears as A<Regen>B and cannot be 
                                                                                                                                            
selected.
^
For setting the user’s bit. (Digit by digit)
Display
: AB CD EF 01
Memo :                                                                                                                                                                                                         
● When [TC Generator] is set to ARegenB, this item appears as A<Regen>B and cannot be 
                                                                                                                                            
selected.
For setting the framing mode of the time code generator.
Non Drop
: Internal time code generator works in the non-drop-frame mode. Use this setting 
when placing emphasis on the number of frames.
: Internal time code generator works in the drop-frame mode. Use this setting when 
placing emphasis on the recording time.
Memo :                                                                                                                                                                                                         
● This item can be set only when the frame rate of [Frame & Bit Rate] in the [Record 
A60pB, A30pB, or A60iB. When the frame rate is A24pB, 
ANon DropB becomes fixed and cannot be selected. When the frame rate is A50pB, A25pB, or 
                                                                                                                                            
GY-HM150U.book  Page 69  Monday, September 5, 2011  1:48 AM