Sony Ericsson PDW-530P Manuel D’Utilisation

Page de 168
Chap
ter
 8
   Set
ting Up th
e C
a
mc
orde
r
118
8-3 Mounting the Lens
Reattaching the eyepiece
1
Align the red marks on the eyepiece locking ring and 
the viewfinder barrel.
2
Align the red mark on the end of the eyepiece end with 
the red marks on the eyepiece locking ring and the 
viewfinder barrel. Then insert the eyepiece into the 
viewfinder barrel.
3
Turn the eyepiece locking ring clockwise until its 
“LOCK” arrow points at the mark on the viewfinder 
barrel.
Note
When the eyecup is worn out, replace it with a new one 
(service part number 3-723-079-03).
(The camcorder was shipped with an eyecup whose part 
number is 3-776-341-01.)
8-3 Mounting the Lens
To mount the lens, proceed as follows.
For information about using the lens, refer to the lens 
manual.
Mounting the lens
1
Push the lens locking lever up and remove the lens 
mount cap from the lens mount.
2
Align the center slot in the lens mount with the center 
pin on the lens, and insert the lens into the mount.
3
Holding the lens in place, push the lens locking lever 
down to mount the lens.
Note
If the lens is not firmly locked, it may come off while 
the camcorder is being used. This could cause a serious 
accident. Make sure the lens is firmly locked. It is 
recommended that the lens mount securing rubber be 
put on the lens-locking lever as illustrated above.
4
Connect the lens cable to the LENS connector.
5
Secure the lens cable with the cable clamps.
Red mark on the end of the eyepiece
Lens mount securing rubber