INSTALLATION
For easy installation, select an existing light with a wall
switch for replacement.
For eave mount only:
Swing the sensor head towards the clamp screw
joint.
If the sensor pops out of the ball joint, loosen the
clamp screw and push the sensor back into the ball
joint. Tighten the clamp screw when done.
Then rotate the sensor head clockwise 180
°
 so
the controls face down.
Wall Mount
Eave Mount
For under eave installation, the sensor head must
be rotated
 as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.
W
IRE
 
THE
 L
IGHT
 C
ONTROL
.
Turn power off at the fuse or circuit breaker.
Remove the existing light fixture.
Install the mounting strap as shown using two
screws that fit your junction box.
The plastic hanger can be used to hold the fixture
while wiring. The small end of the plastic hanger
can be threaded through the hole in the center of the
cover plate. The small end then goes into one of the
slots on the mounting strap.
Route the Light Control’s wires through the large
gasket holes.
Controls
Controls
Controls
Clamp Screw
Shell Slot
White to
White
Black to
Black
Junction box ground wire to
green ground screw on fixture.
Gasket
Mounting
Strap
Mounting
Bolt
Rubber
Plug
M
OUNT
 
THE
 L
IGHT
 C
ONTROL
.
Align the Light Control cover plate and cover plate
gasket. Secure with the mounting bolt.
Align the three slots in the decorative shell with the
lamp holder pins. Push the shell in and then twist
clockwise to lock. Repeat for other shell.
Push the Rubber Plug firmly into place.
Twist the junction box wires and fixture wires together
as shown. Secure with wire connectors.
Lock Nut
To avoid water damage and electrical shock,
keep lamp holders 30
°
 below horizontal.
Adjust the lamp holders by loosening the lock nuts
but do not rotate the lamp holders more than 180
°
from the factory setting. When screwing in the
floodlamps, do not overtighten.
Keep lamps at least
1" (2.5 cm) from the
sensor. Do not al-
low the lamps to
block the lens.
Lens
If a wet location junction box was not used, caulk
the wall plate mounting surface with silicone
weather sealant.