ABRT
The system could not allocate a tone receiver for the test. The
system may be oversized for the number of tone detectors present
or some of the tone detectors may be out of service. Enter list
measurements tone-receiver to display basic information
system may be oversized for the number of tone detectors present
or some of the tone detectors may be out of service. Enter list
measurements tone-receiver to display basic information
about the system's tone receivers.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals up
to 5 times.
1004
ABRT
The port was seized by a user for a valid call.
1. Use display port location to determine the trunk group/
member number of the port. Use status trunk to determine
the service state of the port. If the service state indicates that
the port is in use, then the port is unavailable for certain tests.
Wait until the port is idle before retesting.
the port is in use, then the port is unavailable for certain tests.
Wait until the port is idle before retesting.
2. If the port status is idle, retry the command at 1-minute intervals
up to 5 times.
1018
ABRT
Test disabled by administration. This only applies to analog
stations.
stations.
1. To enable test, set the Test field on the Station Administration
form (change station extension) for the particular analog
station being tested to y.
1020
ABRT
The test did not run due to a previously existing error on the specific
port or because of a more general circuit pack error.
port or because of a more general circuit pack error.
1. Examine the Error Log for existing errors against this port or
circuit pack, and attempt to diagnose the previously existing
error.
error.
S8500
/
G700
:
1412
ABRT
This test does not execute on a G700 Media Gateway.
2000
ABRT
Response to the test request was not received within the allowable
time period.
time period.
1. Retry the command at 1-minute intervals up to 5 times.