Avaya 03-300430 Manuel D’Utilisation
Communication Manager Maintenance-Object Repair Procedures
364 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 1 is an in-line error that can only be resolved over time. No terminal equipment
was present when ringing was attempted. Execute test port location s.
b. Error Type 23: The circuit pack was logically administered but not physically installed. The
alarm will clear when the circuit pack is installed.
c. Error Type 130: The circuit pack was removed or has been insane for more than
11 minutes. To clear the error, reseat or replace the circuit pack.
Table 99: EMBEDDED AUDIX Analog Line/Control Link Error Log Entries
Error
Type
Type
Aux
Data
Data
Associated Test
Alarm
Level
Level
On/Off
Board
Board
Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each
appropriate test’s description, and follow its recommended procedures.
0
Any
Any
Any
test port location sh r 1
1 (
40977
None
18
0
busyout
station ext
WRN
ON
release station extension
23 (
0
None
WRN
OFF
130
(
None
WRN
ON
test port location sh
257
(
40973
None
513
(
Any
None
1025
(
Looparound test
(#161)
MIN
WRN
2
2. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in set options.
ON
test port location l r 2
1281
Conference test
(#7)
MIN
WRN
2
ON
test port location l r 2
1537
NPE Crosstalk test
(#6)
MIN
WRN
2
ON
test port location l r 2