en | Hardware Installation
RAID Subsystem DVA-16K | Installation Manual
F.01U.027.799 | V2 | 2008.08
Bosch Security System
3.6
Rack/Cabinet Installation
The RAID subsystem has been designed to fit into a standard cabinet or rack. Two (2) slide 
rails are available for installing the subsystem into a rack or cabinet. Please contact your sys-
tem vendor for further details. The subsystem should be installed in the rack or cabinet before 
the hard drives and the drive trays are installed. If the drive trays with the associated hard 
drives are installed, the subsystem will be too heavy to mount into a rack or cabinet. When 
installing the subsystem into a rack or cabinet it is advisable that three people assist in the 
mounting process.
To install the subsystem into a rack or cabinet please refer to the installation instructions that 
came with the slide rails.
3.7
Drive Tray Installation
Once the hard drives have been installed in the drive trays, the drive trays can be installed into 
the RAID subsystem.
1.
Make sure the key-lock is in the unlocked position, i.e., the groove on its face is in a hori-
zontal orientation. If the groove is in a vertical position, as shown in Figure 3.1, then the 
key-lock is locked and the front flap on the drive tray cannot be opened.
Fig. 3.1
Front View of an Individual Drive Tray
2.
Open the front flap on the drive tray. (See Figure 3.2) Push the button on the front of the 
drive tray. The front flap will open in an upward direction. 
Fig. 3.2
Drive Tray Front Flap
3.
Align the drive tray with the slot in which you wish to insert it. Make sure that it is resting 
on the rails inside the enclosure. Once the drive tray is lined up with the slot, gently slide 
it in. This should be done smoothly and gently. (See Figure 3.3)
CAUTION! 
All drive trays must be installed into the enclosure even if they do not contain a hard drive. If 
the trays are not installed into the enclosure, the ventilation required for cooling will not be 
normalized and the subsystem will overheat.