 WARNING: Burner will come 
on automatically within one min-
ute after pilot burner is lighted.
6.  Press the buttons 
 and 
 at the same 
time. A short acoustic signal confirms start 
sequence has begun.
 
Further short acoustic signals (0.2 sec., 
1 Hz) indicate the ignition process until it 
is completed and main gas flows. If pilot is 
already lit, motor will turn on (max. flame 
height) while buttons are pressed down. If 
pilot does not light, see Troubleshooting
page 21.
7.  Press 
  to  turn  on  main  burner  and 
increase  flame  height.  Press 
  to  de-
crease  flame  height  and  shut  off  main 
burner.
8.  Short  tapping  of  either  button  allows 
incremental change in flame height.
9.  Press OFF button to switch off main gas 
and pilot gas.
10. To leave pilot lit and shut off burners only, 
press 
  to  decrease  flame  height  and 
shut off main burner.
FUNCTIONS OF 
REMOTE CONTROL
Battery
•  After the charged battery has been correctly 
installed, the remote hand set is ready for 
operations.
•  Remove the battery if the remote handset 
will not be used more than one year.
Changing Code
The  control  is  radio  frequency  operated. A 
code  (chosen  from  among  4,000  available 
codes)  is  preset  for  all  valves,  but  can  be 
changed if required (15 additional codes avail-
able). Change DIP switch position. (The DIP 
switch is located inside the hand held control 
at the top of the battery compartment.) Then 
press the receiver's reset button on the bottom 
of the receiver module until you hear a second 
(longer) signal. When pressing the 
 button 
on the remote handset in the following 20 sec., 
the receiver learns the new code.
oPeRaTIoN
Continued
REMOTE LIGHTING 
INSTRUCTIONS
 WARNING:
•  If  fireplace  has  glass  doors, 
never operate this heater with 
glass doors closed. If you op-
erate heater with doors closed, 
heat  buildup  inside  fireplace 
will cause glass to burst. Make 
sure there are no obstructions 
across openings of fireplace.
•  You must operate this heater 
with  a  fireplace  screen  in 
place.  Make  sure  fireplace 
screen  is  closed  before  run-
ning heater. 
NOTICE: During initial operation 
of new heater, burning logs will 
give off a paper-burning smell. 
Orange flame will also be pres-
ent. Open damper or window to 
vent smell. This will only last a 
few hours. 
 CAUTION: A mild gas flash 
within  10  seconds  is  normal 
during shutdown of this heater. 
Remain clear of the hearth area 
for the entire shutdown process 
to avoid possible injury.
1.  STOP!  Read  the  safety  information, 
page 15.
2.  Make sure equipment shutoff valve is fully 
open.
3.  Turn motor knob clockwise 
 to the 
OFF position.
4.  Wait five (5) minutes to clear out any gas. 
Then  smell  for  gas,  including  near  the 
floor. If you smell gas, STOP! Follow “B” 
in the safety information, column 1. If you 
don’t smell gas, go to the next step.
5.  Make sure ON/OFF switch is in "–" (ON) 
position.