Design Dynamics VF-24N-MHD Manuel D’Utilisation

Page de 28
www.fmiproducts.com
116986-01H
17
oPeRaTIoN
Continued
Shut Off Procedure
To save battery power, press 
 to turn main 
gas  to  pilot  gas.  Press  the  OFF  button  to 
shut off the device including pilot flame. The 
device can be shut off with ON/OFF switch, 
thus disabling remote hand set.
Setting Display ( °C/24h and °F /12h)
Press  and  hold  OFF  and 
  until  display 
changes from °F (and 12 hour clock) to °C 
(and 24 hour clock) or vice versa.
Setting The Time
•  After connecting battery or by simultane-
ously pressing 
 and 
 the display will 
start to flash. You are in the set mode.
•  From SET mode press 
 to set the hour 
and 
 to set the minute.
•  Wait  or  press  OFF  to  return  to  manual 
mode.
Battery Replacement
Remote handset battery needs to be changed 
when LED is dim. Battery life expectancy is 
2 to 3 years. Replacement is recommended 
at the beginning of heating season. Battery 
needs  to  be  changed  when  acoustic  error 
message appears during ignition (see Identify-
ing Error Signals from Receiver,
 page 24).
Changing Mode of Operation
•  Press the SET button quickly to change the 
mode of operation in the following order:
  MAN, 
 TEMP,  TEMP, TIMER.
•  Manual flame height adjustment (MAN ap-
pears on display): Press 
 to turn on the 
fire (main burner) or to increase flame height. 
Press 
 to decrease flame or to go down 
to pilot only. The receiver acknowledges the 
transmission with an acoustic signal.
•  The day time temperature mode (  TEMP 
appears  on  display):  The  sensor  in  the 
transmitter  measures  room  temperature. 
The  controller  compares  the  room  tem-
perature with set temperature and sends 
a signal to the receiver to turn gas valve 
motor up or down, to adjust flame height 
accordingly.
•  The  nighttime  setback  temperature  ( 
TEMP appears on display): The sensor in 
the transmitter measures the temperature 
and  adjusts  it  according  to  the  nighttime 
setback  temperature.  There  is  a  bigger 
temperature differential during this cycle.
•  Timer: The timer mode (TIMER) operates 
much  like  the  temperature  mode  above. 
The timer setting allows you to set specific 
times for on and off. (There are 2 burner 
on and 2 burner off cycles every 24 hours.) 
If  the  reading  for  the  nighttime  temp.  is 
"– – –", the motor will turn off the valve to 
standby pilot position and wait for the next 
burner  on  cycle.  This  display  shows  the 
setting temperature every 30 seconds.
Setting Temperature
•  Select  the  desired  mode  of  operation 
(day or night) by pressing the SET button 
briefly.
•  Hold SET button until display flashes.
•  Set temperature with the 
 or 
 (40°F is 
the minimum temperature).
•  Wait  or  press  OFF  to  go  to  temperature 
control mode.
•  If  temperature  control  in  moon  times 
should be off (lower battery consumption), 
decrease  night  temperature  until  "–  –  –" 
appears on display.
Set Timer
•  Switch to timer mode by pressing the SET 
button briefly.
•  Press the SET button until P1
 flashes.
•  Set hours with 
 and minutes with 
.
•  Press SET briefly for the next burner cycle 
time.
•  If all 4 times are set, pressing the OFF but-
ton or waiting will complete programming.
Shutting Off Heater
Press OFF button on remote control to switch 
off main gas and pilot gas.
Shutting Off Burner Only (pilot stays lit)
Press 
 to decrease the flame height and 
shut off main burner.
SET
OFF
STAND
BY
Figure 18 - Control Panel for Hand-Held 
Remote