Maintenance 
 
To maintain output, the water level in the cylinder will 
slowly move upwards, exposing new electrode to the 
water as the electrodes become coated with minerals. 
Eventually, all of the usable electrode surfaces will be 
coated and the cylinder will be full of water. At this point, 
the output will begin to fall and the red “service" light will 
come on. The unit will shutdown. This indicates the need 
to change the cylinder-typically 500-2000 hours of 
operation, depending on the quality of the fill water 
supply. 
 
To remove the cylinder 
1.  Drain cylinder completely using the 'on-off- drain" 
switch. 
2.  Turn off power to the unit at the external disconnect. 
Disconnect electrode power wires (#38 & #39) and 
cylinder full electrode wire (#29) from the tank. 
These connections are 1/4' quick connects. 
3.  Disconnect 1” tube at top of tank.  
 
 
 
 
 
4.  Remove tank, clean out drain cup and insert with 
new tank. Be sure that "o" ring is in place on the 
cylinder fill/drain neck prior to installation (See 
Figure 11a). New “o" ring is included with each 
replacement cylinder. 
5.  Clean and check both the fill and drain valves while 
servicing the unit. 
6.  Check the strainer. If it is dirty or restricting the 
water-replace it. 
7.  Install cylinder in unit by pushing downward with a 
slight twisting motion, while ensuring proper 
orientation of tank within cabinet. 
8.  Reconnect electrode power wires #38 and #39, and 
cylinder full electrode, wire #29. Make sure that all 
electrical connections are securely tightened. 
9.  Follow cold start-up instructions on page 10. Monitor 
amp draw for several cycles.    
.
 
 
Extended Shutdown 
Always drain cylinder completely if unit will be off for an 
extended period of time. This will preserve the life of the 
cylinder. 