Herrmidifier Co 6000 Manuel D’Utilisation

Page de 24
Key Features 
 
Adjustable Setpoints 
Capacity 
•  Range = 50-100% 
•  Preset at 100% for 6000-1,3,4 
Preset at 50% for 6000-2 
 
Low Drain Threshold 
•  Range = 50-100% 
•  Preset at 90% 
 
Cycle Time 
•  Range = 60-300 seconds 
•  Preset at 60 seconds 
 
Faults 
Overcurrent 
•  138% of Rated Current 
•  System Shutdown 
 
 
 
 
 
 
Fill System 
•  Fill valve open for 6 hours without achieving capacity setpoint or cylinder full 
•  System Shutdown 
 
End of Cylinder Life 
•  6 hours of operation while on cylinder full without achieving capacity setpoint 
•  System Shutdown (See Pg. 14 for Manual Override) 
 
 
Conductivity* 
Micromhos 
(approx.) 
Average Life** 
Expectancy – Hrs. 
(approx.) 
100 2000 
135 1900 
170 1800 
250 1300 
500 800 
750 650 
1000 500 
*If the conductivity of your supply water is less than 100 micromho, consult Herrmidifier for specific circuit board 
adjustments and replacement tank information (GT-176-1). 
Unit performance may be affected. 
Operation on water of less than 60 micromho is not recommended. 
**Your actual cylinder life may be higher or lower depending on the exact composition of your water supply. 
 
 
5