NOTE: Take care not to scratch fan housing when
installing blades.
9.
You have now completed the assembly of your new
ceiling fan. You can now proceed with hanging and
the electrical wiring of your fan.
BLADE ASSEMBLY
BLADE FLANGE
SCREWS
4. Reinstall the two setscrews in the motor coupling.
While pulling up on the hanger ball, securely
tighten the setscrews. (Figure 1).
NOTE: The setscrews must be properly installed
as described above, or fan wobble could result.
5. 
The fan comes with the blue, black, and white leads
that are 80” long. Before installing fan, measure up
approximately 6 to 9-inches above top of hanger
ball/downrod assembly. Cut off excess leads and
strip back insulation 1/2-inch from end of leads.
6. Turn fan assembly upside down in preparation for
mounting fan blade assemblies.
IMPORTANT: THE SIDE OF THE FAN BLADE
HAVING THE RIB LINE MUST BE FACING
UPWARDS AS SHOWN IN FIGURE 2.
7.
Mount blade flanges to fan blades using three 3/16-
24 x 1/2" screws per blade (Figure 2).
8.Attach blade assembly to motor hub using two
1/4-20 x 7/16" blade flange screws. Make sure the
screws are tightened securely (Figure 3). Repeat
this procedure for other four blade assemblies.
3/16-24 x 1/2" SCREW (3)
RIB LINE
THIS SIDE UP
FAN BLADE
BLADE FLANGE
Figure 2
Figure 3
4
MOTOR COUPLING
CEILING
COVER
CLEVIS
PIN
HAIRPIN
CLIP
CLEVIS
PIN
HANGER BALL/
DOWNROD ASSEMBLY
SETSCREW
SETSCREW
Figure 1
Your new ceiling fan will require a grounded electrical
supply line of 120 volts AC, 60 Hz, 15 amp circuit.
The outlet box must be securely anchored and
capable of withstanding a load of at least 50 pounds.
If your fan is to replace an existing ceiling light fixture,
turn electricity off at the main fuse box at this time
and remove the existing light fixture.
Electrical Requirements
To reduce the risk of personal injury, do not bend the
blade flanges when installing the blades or cleaning
the fan. Do not insert foreign objects between
rotating fan blades.
WARNING
!
To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked acceptable for
fan support, and use screws supplied with outlet
box. Most outlet boxes commonly used for support
of light fixtures are not acceptable for fan support
and may need to be replaced. Consult a qualified
electrician if in doubt.
WARNING
!
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is
turned off at the main fuse box before wiring. All
wiring must be in accordance with National and
Local codes and the ceiling fan must be properly
grounded as a precaution against possible electrical
shock.
WARNING
!
To avoid fire or shock, follow all wiring instructions
carefully.
Any electrical work not described in these
instructions should be done or approved by a
licensed electrician.
WARNING
!