Rinnai REU-V2520FFUD Manuel D’Utilisation

Page de 48
103 International Drive
Peachtree City, Georgia  30269
RINNAI WATER HEATERS
Domestic Hot Water with Circulation
1 Rinnai Water Heater
This is not an engineered drawing, it is intended only as a guide and 
not as a replacement for professionally engineered project drawings. 
This drawing is not intended to describe a complete system, it is up 
to the contractor/engineer to determine the necessary components 
for and configuration of the particular system being installed.  The 
drawing does not imply compliance with local building code 
requirements.  It is the engineer/contractor responsiblity to ensure 
the installation is in accordance with all local building codes.  Confer 
with local building officials before installation.
Pressure Relief Valve
3/4" Ball Valve
3/4" Union
Check Valve
S
Pressure Regulator
Circulating Pump
Solenoid Valve
Boiler Drain Valve
KEY
Minimum 3/4" Hot Water 
 Supply Line
Building Fixture Outlets
(Optional)
2-6 Gallon
Storage Tank
(To eliminate cold water
sandwich effect caused by 
frequent On/Off operation)
Pump Should be Controlled by an 
Aquastat, Timer or Combination 
Aquastat and Timer 
Pump to be sized for 3.0 gpm flow @ 12 feet head.  Flow Balancing 
Valve to be adjusted to 3 GPM flow through water heater with no hot 
water taps open.  Pump to be of Bronze or Stainless Construction.
Cold Water Supply and Circulation Return Lines Must Be 3/4" 
Tubing Throughout Circulation Loop.
Note: 
Water heater outlet temperature 
cannot be adjusted when 
circulation pump is running.
QTY
1
1
1
Expansion Tank
Rinnai
Water Heater
Note:
PLEASE NOTE FOR RESIDENTIAL 
APPLICATIONS, THIS PIPING 
ARRANGEMENT REDUCES 
WARRANTY TO THE FOLLOWING:
3 Years On Heat Exchanger
3 Years On Parts
Rinnai
Equipment List 
(Residential and 
Commercial)
Rinnai
Water Heaters
(Indoor)
MC-91 Controller
(Included)
MC-100V and BC-100V 
Controllers Optional
RIK-KIT (Optional)
(3/4" Fittings Include:
2 Unions, 2 Ball Valves,
2 Drain Valves and 
1 Pressure Relief Valve.) 
3/4" Gas Connection
Commercial Application Warranty:
5 Years On Heat Exchanger
5 Years On Parts
Gas Supply
Venting Equipment List
(Residential and
Indoor Unit
Please Review Venting
Instructions/Guidelines for
Proper Components and
Installation.
Commercial)
Rinnai America
FF  Models
I N S TA L L E R ’ S  I N S TA L L AT I O N  I N S T R U C T I O N S
OPTIONAL PIPING FOR CIRCULATION SYSTEMS