Sterling SDA 150-380 Manuel D’Utilisation

Page de 52
 
 
Cabinet Series Dehumidifying Dryer 
 
15 
Chapter 4:  Controls 
4-1  Control Panel Indicator Lights and Switches 
Rocker Switches 
System ON/OFF Rocker Switch 
Used to de-energize control power to the indicator panel, allowing separate control of the dryer 
and conveying systems. 
Dryer ON/Sequence Shutdown Rocker Switch 
Used to start the dryer.  Move this switch to the Sequence Shutdown position to turn off the 
process heaters, finish the regeneration cycle and then turn off the dryer. 
Optional Alarm Silence Rocker Switch 
Press the Alarm Silence switch to silence the horn when a high temperature alarm activates. 
The alarm repeats every five minutes until the problem causing the alarm condition is cleared. 
Indicating Lights 
 
Indicator 
Name 
Description 
G
 
Regen Blower 
On Light 
The Regen Blower On indicator lights when the 
regeneration blower energizes. 
G
 
 
Left Bed In 
Regen Light 
The Left Bed In Regen LED lights when the left bed 
is in regeneration. 
G
 
 
Left Bed Heater 
Light 
The Left Bed Heater indicator lights when the left 
bed regenerates and is in the heat-up portion of the 
regeneration cycle. 
G
 
 
Right Bed In 
Regen Light 
The Right Bed In Regen LED lights when the right 
bed is in regeneration. 
 
G
 
Right Bed Heater 
Light 
The Right Bed Heater indicator lights when the right 
bed regenerates and is in the heat-up portion of the 
regeneration cycle. 
G
 
Process Blower 
On Light 
The Process Blower On indicator lights when the 
process blower energizes. 
G
 
Process Heater 
On Light 
The Process Heater On indicator lights when the 
process air heater is energized. 
R
 
Low Compressed 
Air Light 
The Low Compressed Air alarm indicator lights 
when the dryer compressed air supply drops below 
60 psi (413kPa/ 4.13 bars).  Upon loss of