Regency B36X Manuel D’Utilisation

Page de 64
28
Regency Bellavista™ B36X  Gas Fireplace
INSTALLATION
HORIZONTAL VENTING WITH TWO (2) 90
O
 ELBOWS
(RIGID PIPE 4" X 6 - 5/8")
16
2
2
0
0
12
12
6
6
18
4
49"
(1245mm)
Minimum
Height
Requirement
4
14
8
8
10
10
14
16
18
20
V
ertical
Height
(Feet)
Horizontal (Feet)
Restrictor 1” Open
Restrictor 2” Open
VENTING ARRANGEMENTS HORIZONTAL TERMINATION 
(MUST USE REDUCER PART # 946-606 & 770-994 RIGID PIPE ADAPTOR)
(RIGID PIPE 4" X 6-5/8") 
The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90
o
 two  45
elbows equal one 90
o
 elbow).
•   Maintain clearances to combustibles 
as listed in "Clearances" section
•   Horizontal vent must be supported 
every 3 feet.
•   Firestops are required at each fl oor 
level and whenever passing through a 
wall.
•  A wall thimble is mandatory for all 
horizontal terminations due to high 
temperatures.
ALL RIGID PIPE SYSTEMS
 4" INNER DIAMETER
6-5/8" OUTER DIAMETER
H
H1
V
Option      V 
     H + H1
     A) 
0'  Min.       2' Max.
     B) 
1'  Min.       3' Max.
     C) 
2'  Min.       4' Max.
     D) 
3'  Min.       5' Max.
     E) 
4'  Min.       6' Max.
     F) 
5'  Min.       7' Max.
     G)  6' Min.           
 77''7' 
W i t h   t h e s e   o p t i o n s , 
maximum total pipe length 
is 30 feet with minimum 
of 6 feet total vertical 
and maximum 8 feet total 
horizontal.
Please note minimum 1 
foot between 90
o
 elbows 
is required.
One 90
o
 elbow = Two 45
o
 elbows.
Lengths do not include elbow indicated.
Must use reducer # 946-606 and rigid pipe adaptor #770-994.
Vent Restrictor Set at 2" Opening
8' Max.