Regency B36X Manuel D’Utilisation

Page de 64
29
Regency Bellavista™ B36X Gas Fireplace
HORIZONTAL VENTING WITH THREE (3) 90
O
 ELBOWS
(RIGID PIPE 4" X 6 - 5/8")
V1
H1
H
V
Lengths do not include elbow indicated.
Must use reducer # 946-606 and rigid pipe adaptor #770-994. 
     
Option      V 
   H         V + V1   H + H1
     A) 
0' Min.  1' Max.  1' Min.   2' Max.
     B) 
1' Min.  2' Max.  3' Min.    3' Max.
     C) 
2' Min.  2' Max.  5' Min.   4' Max.
     D) 
3' Min.  2' Max.  7' Min.    5' Max.
     E) 
4' Min.  3 Max.  9' Min.   6' Max.
     F) 
5' Min.  4' Max.  10' Min.   7' Max.
     G) 
6' Min.  5' Max.  11' Min.   8' Max.
     H) 
7' Min.  6' Max.  12' Min.   9' Max.
With these options, 
max. total pipe length 
is 30 feet with min. of 
12 feet total vertical 
and max. 9 feet total 
horizontal.
Please note min. 1 
foot between 90
o   
elbows is required.
One 90
o
 elbow = Two 45
o
 elbows.
Vent Restrictor - Full Open/ No Restrictor Installed
V
H1
H
V1
VERTICAL VENTING WITH THREE (3) 90
O
 ELBOWS
(RIGID PIPE 4" X 6 - 5/8")
INSTALLATION
Option        V 
H + H1  V + V1
     A) 
0' Min.  2' Max.  2' Min.
     B) 
1' Min.  2' Max.  3' Min.
     C) 
2' Min.  3' Max.  4' Min.
     D) 
3' Min.  4' Max.  6' Min.
     E) 
4' Min.  5' Max.  7' Min.
     F) 
5' Min.  6' Max.  8' Min.
     G) 
6' Min.  7' Max.   9' Min.
     H) 
7' Min.  8' Max.  10' Min. 
With these options, max. 
total pipe length is 30 feet 
with min. of 10 feet total 
vertical and max. 8 feet 
total horizontal.
Please note min. 1 foot 
between 90
o
 elbows is 
required.
One 90
o
 elbow = Two 45
o
 elbows.
Lengths do not include elbow indicated.
Must use reducer # 946-606 and rigid pipe adaptor #770-994
Vent Restrictor Set at 2" Opening