PGS TC36 AR Manuel D’Utilisation

Page de 36
050505-36 
36ARB2     17
     36"
    24"
     48"
 ADJACENT
    24"
(91.5 cm)
(61 cm)
(61 cm)
(122 cm)
STRUCTURES
OR FENCE
VENT TERMINAL 
CLEARANCE
Minimum clearances to the vent terminal 
must be maintained as shown in fi gure #22a 
& b. Measure clearances to the nearest 
edge of termination hood.
NOTE:  Vent terminal must not be 
recessed into a wall or siding.
NOTE:  LOCAL CODES OR REGULA-
TIONS MAY REQUIRE DIFFERENT 
CLEARANCES.
Fig. # 22b
VENT TERMINAL MINIMUM 
CLEARANCES
A=  clearances above grade, veranda, porch, deck, or balcony
 
[* 12 inches (30 cm) minimum]
B=  clearance to window or door that may be opened [* 12 
inches (30 cm) minimum]
C=  clearance to permanently closed window [minimum 12 
inches (30 cm) recommended to prevent condensation on 
window]
D=  vertical clearance to ventilated soffi t located above the ter-
minal within a horizontal distance of 2 feet (60 cm) from the 
edge of the terminal [30 inches (76 cm) minimum]
E=  clearance to unventilated soffi t [30 inches (76 cm) minimum]
F=  clearance to outside corner [6 inches (15 cm) minimum]
G=  clearance to inside corner [6 inches (15 cm) minimum]
H=  * not to be installed above a meter/regulator assembly within 
3 feet (90 cm) horizontally from the center-line of the regula-
tor
I=  clearance to service regulator vent outlet [* 6 feet (1.8 m) 
minimum]
J=  clearance to non-mechanical air supply inlet to building or 
the combustion air inlet to any other appliance [* 12 inches 
(30 cm) minimum]
K=  clearance to a mechanical air supply inlet [* 6 feet (1.8 m) 
minimum]
L=  ^ clearance above paved side-walk or a paved driveway 
located on public property [* 7 feet (2.1 m) minimum]
M=  clearance under veranda, porch, deck, or balcony [30 
inches (76 cm) minimum**]
 
^  a vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and 
serves both dwellings*
 
**  only permitted if veranda, porch, deck, or balcony is fully open on a minimum of 2 sides beneath the fl oor*
 
*  as specifi ed in CGA B149 Installation Codes, Note: local Codes or Regulation may require different clearances
AIR SUPPLY INLET
VENT TERMINAL
GAS METER
FIXED
CLOSED
FIXED
CLOSED
OPEN-
ABLE
OPEN-
  ABLE
INSIDE 
CORNER 
DETAIL
AREA WHERE TERMINAL 
IS NOT PERMITTED
M
K
I
A
V
G
G
H
A
J
V
G
A
B
C
A
V
V
A
V
B
F
B
L
V
E
V
V
V
D
Fig. # 22a
VENT TERMINAL MINIMUM 
CLEARANCES TO ADJACENT 
STRUCTURES