PGS TC36 AR Manuel D’Utilisation

Page de 36
050505-36 
36ARB2     25
Fig. # 35
THERMOCOUPLE
THERMOPILE
PILOT FLAME
ELECTRODE
APPENDIX A
MAINTENANCE
Caution:  Turn off gas and electrical power supply (if appli-
cable) and allow ample time for unit to cool before servicing 
appliance.  It is recommended that the fi replace and its vent-
ing should be inspected at least once a year by a qualifi ed 
service person.
Glass Panel:
Warning:
  Do not operate fi replace with glass panel removed, 
cracked or broken. Replacement of the glass panel should be 
done by a licensed or qualifi ed service person.
Do not strike or otherwise impact the glass in anyway that may 
cause it to break. If the glass becomes cracked or broken, 
it must be replaced before using the fi replace. Replacement 
glass can be obtained from your nearest Town and Country 
Fireplaces
TM
 dealer. The size required is 36" x 30" x 5mm. 
Use ceramic glass only.  Do not substitute with any other 
type.
To remove broken glass, remove window frame as noted in 
"Window Frame Removal" section.
Unclip the Glass Retainer Clips located at the top of the Win-
dow Frame. Pull the top edge of the glass out of the frame 
fi rst, then lift it up and out of the bottom edge.
Install the new piece of glass with the gasket into the frame 
so that the thicker bead of gasket faces the fi replace.
Annual Inspection:
a)  Remove glass panel and log set. Inspect logs and burner 
assembly for soot buildup. If excessive buildup of soot is 
present, have a qualifi ed service person inspect and adjust unit 
for proper combustion. Clean logs and burner with a brush or 
vacuum cleaner, paying close attention to burner ports.
b)  Check the pilot system for proper fl ame size and opera-
tion. Clean pilot free of soot, dust or any other deposits. (See 
Fig. #35 and 36)
c)  Check that the vent pipe and vent terminal are open and 
free from blockage or debris. If the venting is disassembled 
for cleaning, it must be properly assembled and re-sealed. 
Refer to VENTING section for proper procedure.
d)  Check glass panel gasket, replace if necessary. It is important 
that the glass seal be maintained in good condition.
e)  Check and replace batteries as needed.
Note:  The appliance area must be kept clear and free from 
combustible materials, gasoline and other fl ammable vapours 
and liquids. 
Periodically:
a)  Viewing glass may be cleaned as necessary with fi replace 
glass cleaner.
b)  Exterior fi nish may be cleaned with mild soap and water.
CAUTION:
 
Do not use abrasive cleaners on glass or any other 
part of the fi replace.
 
Do not clean glass when hot.
PILOT FLAME
FLAME SENSOR
ELECTRODE
Fig. # 34
MILLIVOLT PILOT
ELECTRONIC PILOT