Remington QFP40 Manuel D’Utilisation

Page de 68
Page 53
REMINGTON QFP40 Direct Vent FIREPLACE
250-4721   JUNE 2001
All arched and rectangular fascia attach to four flanges located two to each side of the
glass frame.  Insert and finger start bolts tightening with the 5/32" Allen wrench supplied with
unit.
INSTALLING GLASS
The glass assembly has a narrow metal edge at top of the frame, and wide metal edge at
bottom of the frame.   To install the glass assembly, lift and set the bottom T-bar extensions onto
the  bottom  alignment  pins  located  at  the  edge  of  firebox--refer  to  diagram  below.    With    the
bottom  edge  of    glass  assembly  resting  on  the  bottom  alignment  pins,  lift  up  and  onto  the  top
alignment pins.  Secure the assembly to zc appliance with the spring latches, two on top and two
at bottom.
GLASS 

F
ASCIA
Flanges  for  fas-
cia  attachment,
and  T-bar  exten-
sions  for  setting
glass onto align-
ment pins.
(2 per side)
Alignment pins.
(2 per side)
Spring Latches.
(2 upper & 2 lower)
INSTALLING FASCIA
Insert bolts through
these holes and into
Flanges shown in
picture above. (2 per
side)
T-bar extension
of Flange.
Narrow Edge (TOP)
Wide Edge (BOTTOM)
WARNING:  Use care in handling of glass assembly, do not strike or slam as this
could cause breakage.