Remington QFP40 Manuel D’Utilisation

Page de 68
REMINGTON QFP40 Direct Vent FIREPLACE
Page 54
250-4721   JUNE 2001
LEAK TEST
1.
Turn on gas to the fireplace.
2.
Turn on gas at the manual shutoff valve.
3.
Leak test all gas joints prior to starting the appliance.
4.
Familiarize yourself with the control panel components, see page 58.
5.
Follow Lighting Instructions on next page to light the pilot and then the main burner.
6.
Leak test all gas joints again.
7.
Check the pilot flame ensuring that it looks like the illustration below.  Adjust the
pilot flame if necessary.
INITIAL START-UP:  NORMAL OCCURRENCES
Fumes  from  curing  paint  and  oil  burning  off  the  steel  is  a  normal  occurrence.    Open
window to vent the area until fumes disappear.
Condensation appearing on the glass each time you start the fireplace is also normal.
Blue Flames will occur on the initial start-up.  After fifteen minutes the flames will become
the yellow/orange flame color.
Remote Wall Switch:  If you install a remote wall switch to operate the fireplace, leave
the ON/OFF switch on the fireplace control panel in the “ON” position.
✔ Do not place any combustible items on top of or directly in front of the fireplace,
even  temporarily.    The  optional  thermostat  may  start  the  fireplace  causing  a
combustible item to ignite.
✔ If the fireplace turns on and off frequently while using the thermostat, you may
want to adjust the flame height down until it produces just enough heat needed,
or relocate the thermostat further away from the fireplace.
LEAK 
TEST/ST
A
R
T
-UP
WARNING!      You must clean all finger-
prints  and  oils  from  any
gold surface prior to firing
the  fireplace  for  the  first
time.
Thermocouple
Thermopile
Pilot Hood
Flames
Piezo Igniter