PROVISIONS FOR ADEQUATE COMBUSTION & VENTILATION AIR
Minimum Dimensions For Solid Fuel Burning Fireplaces UL127 
Factory Built Fireplaces (Figure 2)
Model 
D
VFSV-16 
18" 
11 1/2" 
24" 
18"
VFSR-16 
18" 
11 1/2" 
24" 
18"
VFSV-18 
17" 
14" 
28" 
17"
VFSR-18 
17" 
14" 
28" 
17"
VFSM-18 
21" 
14" 
32" 
17"
VFSV-24 
23" 
14" 
30" 
18"
VFSR-24 
23" 
14" 
30" 
18"
VFSM-24 
27" 
14" 
34" 
18"
VFSV-30 
26" 
14" 
34" 
20"
VFSR-30 
26" 
14" 
34" 
20"
VFSM-30 
30" 
14" 
38" 
20"
The dimensions shown and defined in the fireplace manufacturer’s 
instructions are minimum clearances to maintain in installing this 
heater. Left and right clearances are determined when facing the 
front of the heater.
CLEARANCES
Figure 2
This heater shall not be installed in a confined space unless provisions 
are provided for adequate combustion and ventilation air.
The National Fuel Gas Code defines a confined space as a space whose 
volume is less than 50 cubic feet per 1,000 Btu per hour (4.8m
3
 per kw) 
of the aggregate input rating of all appliances installed in that space and 
an unconfined space as a space whose volume is not less than 50 cubic 
feet per 1,000 Btu per hour (4.8 m
3
 per kw) of the aggregate input rating 
of all appliances installed in that space. Rooms communicating directly 
with the space in which the appliances are installed, through openings 
not furnished with doors, are considered a part of the unconfined space.
Unusually Tight Construction
The air that leaks around doors and windows may provide enough fresh 
air for combustion and ventilation. However, in buildings of unusually 
tight construction, you must provide additional fresh air.
  Unusually tight construction is defined as construction where:
a.  Walls  and  ceilings  exposed  to  the  outside  atmosphere  have  a 
continuous water vapor retarder with a rating of one perm or less 
with openings gasketed or sealed, and
b.  Weatherstripping has been added on openable windows and doors, 
and
c.  Caulking or sealants are applied to areas such as joints around 
window and door frames, between sole plates and floors, between 
wall-ceiling joints, between wall panels, at penetrations for plumb-
ing, electrical, and gas lines, and at other openings.
  If your home meets all of the three criteria above, you must provide 
additional fresh air. 
Warning: If the area in which the heater may be operated is smaller than 
that defined as an unconfined space or if the building is of unusually tight 
construction, provide adequate combustion and ventilation air by one 
of the methods described in the National Fuel Gas Code, ANSI Z223.1, 
Section 5.3. or applicable local codes.
Example of Large Room with 1/2 Wall divider.
Figure 1
The following formula can be used to determine the maximum heater rating 
per the definition of unconfined space:
Btu/Hr = 
(L
1
 + L
2
)FT x (W)FT x (H)FT
 x 1000
50
If the area in which the heater may be operated is smaller than that defined 
as an unconfined space, provide adequate combustion and ventilation air 
by one of the methods described in the National Fuel Gas Code, ANSI 
Z223.1, Section 5.3.
Adhere  to  all  codes,  or  in  their  absence,  the  latest  edition  of  THE 
NATIONAL FUEL GAS CODE ANSI Z223.1 or NFPA54 which can be 
obtained from:
 
American National Standards Institute National Fire Protection Association, Inc.
 
11 West 42nd St. 
Batterymarch Park
 
New York, NY 10018 
Quincy, MA 02269
Glass Doors
Make sure that glass doors are open during all operations of 
the  logset. The  opening  of  the  glass  door  frame  should  be 
the  dimension  used  for  the  minimum  front  opening  of  the 
firebox.
Follow these instructions to ensure safe 
installation.
Failure to follow 
instructions exactly 
can create a fire 
hazard.