FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result caus-
ing property damage, personal injury or loss of life.
A.   This appliance has a pilot which must be lighted by hand. 
When lighting the pilot, follow these instructions exactly.
B.   BEFORE LIGHTING smell all around the appliance area 
for gas. Be sure to smell next to the floor because some gas 
is heavier than air and will settle on the floor.
 
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; 
  Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's 
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire 
department.
C.   Use only your hand to push in or turn the gas control 
knob. Never use tools. If the knob will not push in or 
turn by hand, don't try to repair it; call a qualified service 
technician. Force or attempted repair may result in a fire 
or explosion.
D.   Do not use this appliance if any part has been under 
water. Immediately call a qualified service technician 
to inspect the appliance and to replace any part of the 
control system and any gas control which has been under 
water.
LIGHTING INSTRUCTIONS
1.  STOP! Read the safety information above.
2.  Turn off all electric power to the appliance (if applicable).
3.  Push in manual gas control knob slightly and turn clockwise                     
to “OFF”. Do not force. SR-18 OR SR-30 KNOB 
SHOWN.
4.  Wait ten (10) minutes to clear out any gas. Then smell for 
gas, including near the floor. If you smell gas, STOP! Fol-
low “B” in the safety information above. If you don’t smell 
gas, go to the next step.
5.  Find  pilot  -  the  pilot  is  at-
tached  at  the  bottom  of  the 
burner assembly .
6.  Turn manual gas control knob  
counterclockwise
 
to "PILOT." 
7.  Push in manual gas control knob all the way and hold in. 
Repeatedly push the piezo ignitor button until pilot is lit (or 
use a match to light pilot). Continue to hold the control knob 
in for about one (1) minute after the pilot is lit. Release knob 
and it will pop back up. Pilot should remain lit. If it goes out, 
repeat steps 3 through 7.
• If knob does not pop up when released, stop and imme-
diately call your service technician or gas supplier.
• If the pilot will not stay lit after several tries, turn the gas 
control knob to “OFF” and call your service technician or 
gas supplier.
8. Three heat settings can be selected by slightly depressing the 
manual gas control knob and turning the manual gas control 
knob counterclockwise
to:
 
Position 1 (SR-6, SR-10, SR-18 or SR-30)
 
Position 2   (SR-18 or SR-30)
 
Position 3   (SR-18 or SR-30).
9.  CAUTION! When  the  manual  gas  control  knob  has  been 
turned to desired heat setting, ensure the manual gas control 
knob is locked into that heat setting and cannot be turned 
without being depressed.
If the manual gas control knob is in mid-position, between 
heat settings, incomplete combustion will take place, causing 
odor, and may produce gas leakage or carbon monoxide.
10.  Turn on all electric power to appliance (if applicable).
TO TURN OFF GAS TO APPLIANCE
1.   Turn off all electric power to appliance if service is to be 
performed (if applicable).
2.   Push in manual gas control knob slightly and turn 
clockwise 
 to "OFF". Do not force.
LIGHTING INSTRUCTIONS