Empire Comfort Systems SR-30 Manuel D’Utilisation

Page de 24
16942-5-0907
Page 14
SR-6 Main Burner Flame (Figure 15)
The main burner flame will have a red-orange glow over the sur-
face of the ceramic plaque. The red-orange glow on the surface of 
the ceramic plaque will have a pattern in the shape of a number 
1. The perimeter of the ceramic plaque [approximately the out-
side 1/4"(6mm)] will not glow. A few small, hairline cracks may 
form over the surface of the ceramic plaques or at the edges of 
the ceramic plaques where they have been cemented into position 
on the burner assembly frame. These small, hairline cracks will 
not affect the operation or performance of the ceramic plaques. 
Only, when large cracks develop, with blue flames escaping from 
the large cracks, should you contact your QUALIFIED SERVICE 
PERSON.
SR-10, SR-18 and SR-30 Main Burner Flame (Figure 16)
The main burner flame will have a red-orange glow over the sur-
face  of  the  ceramic  plaques. A  few  small,  hairline  cracks  may 
form over the surface of the ceramic plaques or at the edges of the 
ceramic plaques where they have been cemented into position on 
the burner assembly frame. These small, hairline cracks will not 
affect the operation or performance of the ceramic plaques. Only, 
when large cracks develop, with blue flames escaping from the 
large cracks, should you contact your QUALIFIED SERVICE
PERSON.
A red-orange haze that is visible on the ceramic plaques is accept-
able. A blue flame that rolls out at the top of the ceramic plaques 
indicates an accumulation of dust, lint or spider webs inside the 
casing  assembly  and  main  burner  assembly.  Use  the  following 
procedure to inspect the casing assembly and main burner assem-
bly.
1.  Turn OFF gas supply to the heater.
2.  Turn OFF electric supply to the heater if optional blower is 
installed in heater.
3.  Remove lower louver from casing assembly ( 2 screws).
4.  Remove reflector from casing assembly (2 screws).
5.  Inspect interior of casing assembly for accumulation of dust,  
lint  or  spider  webs.  If  necessary,  clean  interior  of  casing 
assembly with a vacuum cleaner or apply air pressure. Do 
not damage any components within casing assembly when 
you are cleaning.
6.  Remove  pilot  bracket  from  main  burner  assembly  (2 
screws).
7.  Pivot pilot bracket with attached pilot away from main burner 
assembly (do not damage pilot tubing).
8.  Inspect  main  burner  orifice(s)  through  the  rectangular 
opening(s) in the venturi (throat) of the main burner(s). Dust, 
lint and spider webs can accumulate on top of the main burn-
er orifice(s). If necessary, clean main burner orifice(s) with a 
vacuum cleaner or apply air pressure. To thoroughly clean the 
main burner orifice(s) proceed to Step 9.
9.  Disconnect supply tubing from orifice holder(s).
10.  Remove orifice holder from venturi of main burner assembly 
(1 screw for each orifice holder).
11.  Remove main burner orifice from orifice holder.
12.  Apply  air  pressure  through  main  burner  orifice  and  orifice 
holder to remove dust, lint or spider webs.
SR-6 
Figure 15
SR-30 Shown
Figure 16
13.  Apply air pressure into ceramic plaque(s) to remove dust, lint 
or spider webs.
14.  As parts are being replaced in reverse order, check for gas 
leaks at all gas connections before lower louver is replaced 
onto casing assembly.
MAIN BURNER FLAME CHARACTERISTICS