Empire Comfort Systems SR-30 Manuel D’Utilisation

Page de 24
16942-5-0907
Page 9
Figure 5 (SR-10)
CEILING
WINDOW SILL OR SHELF
24” MIN
(610mm)
14” MIN
(356mm)
12” MAX
(305mm)
0” (0mm) CLEARANCE
TO REAR WALL
SIDE VIEW
2” MIN
(51mm)
FLOOR
Figure 6 (SR-10)
FLOOR
CEILING
SIDE WALL
24” MIN
(610mm)
14” MIN
(356mm)
6” MIN
(152mm)
6” MIN
(152mm)
2” MIN
(51mm)
When facing the front of the appliance the following minimum 
clearances to combustible construction must be maintained.
Left side 6 inches (152mm). Right side 6 inches (152mm).
Do not install in alcove or closet. 
Rear wall 0 inches (0mm). Ceiling 36 inches (914mm).
Minimum  vertical  clearance  from  a  projection  above  the 
appliance (shelves, window sills, etc.) 36 inches (914mm).
Floor (top surface of carpeting, tile, etc.) 2 inches (51mm).
Provide adequate clearances around air openings.
Adequate accessibility clearances for purposes of servicing and 
proper operation must be provided.
FLOOR
2” MIN
(51mm)
6” (152mm)
MIN
6” (152mm)
MIN
SIDE WALL
CEILING
36” (914mm) MIN
Figure 7 (SR-18)
SR-18 CLEARANCES