Desa CGF280PT Manuel D’Utilisation

Page de 40
15
102665
INSTALLING
Continued
Mantel Clearances for Built-In Installation
If placing mantel above built-in fireplace, you must meet minimum clearance
between mantel shelf and top of fireplace opening.
Distances to 
Underside of
Mantel 
Underside of
Mantel Shelf
20"
24
1/2
"
27
1/2
"
30"
All minimum 
distances are
in inches
Top of 
Fireplace 
Opening 
1
/2
"
6"
8"
10"
Figure 15 - Minimum Mantel Clearances for Built-In Installation
Mantel Shelf
INSTALLING GAS PIPING TO FIREPLACE LOCATION
NOTICE
A qualified service person must connect fireplace to gas supply.
Follow all local codes.
 CAUTION
Never connect heater directly to the propane/LP supply. This heater
requires an external regulator (not supplied). Install the external
regulator between the heater and propane/LP supply.
Installation Items Needed
Before installing fireplace, make sure you have the items listed below.
• external regulator (supplied by
installer, see Figure 16, page 16)
• piping (check local codes)
• sealant (resistant to LP gas)
• manual shutoff valve *
• test gauge connection *
• sediment trap
• tee joint
• pipe wrench
• approved flexible gas line with
gas connector
 (if allowed by
local codes)
 (not provided)
Continued
*  An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Purchase the optional A.G.A. design-certified
manual shutoff valve from your dealer. See Accessories, page 38.
If your installation does not meet the above minimum clearances, you must:
• raise the mantel to an acceptable height, OR
• remove the mantel.