Desa CGF280PT Manuel D’Utilisation

Page de 40
17
102665
INSTALLING
Continued
Continued
* Purchase the optional A.G.A. design-certified manual shutoff valve from your
dealer. See Accessories, page 38.
A.G.A. Design-Certified Manual Shutoff Valve
With 1/8" NPT Tap*
3" Minimum
From External Regulator
(11" W.C. to 14" W.C.
Pressure)
Approved
Flexible
Gas Line
Tee Joint
Pipe Nipple
Cap
Sediment
Trap
Figure 17 - Gas Connection
CONNECTING FIREPLACE TO GAS SUPPLY
Installation Items Needed
• 5/16" hex socket wrench or nut-driver
• Phillips screwdriver
• sealant (resistant to LP gas, not provided)
1. Remove fireplace screen. Remove two screws that hold fireplace screen in
place for shipping. These screws are located near top of screen. Discard screws.
Lift fireplace screen up and pull out to remove.
2. Remove access door from rear or side of fireplace. See Product Identification,
page 4, for access door locations.
3. Remove screws that attach log base assembly to fireplace. Carefully lift up log
base assembly and remove from fireplace (see Figure 18).
Figure 18 - Removing Log Base Assembly From Fireplace
WARNING ICON
G 001
 CAUTION
Do not pick up log base assembly by burners. This could damage
burners. Only handle base by grates.