Harman Stove Company XL Manuel D’Utilisation

Page de 34
Installation
Only For Qualified Installers
Natural Gas Kit 
Part No. 1-00-00384
LP  Kit 
 
Part No. 1-00-00385
Conversion label
Pilot Orifice
 Main Orifice #31 (Nat. Gas)
 Main Orifice #50 (LP)
Valve Conversion Module
Conversion 
Instructions
These kits are only for use in the 
ShadowLight XL Insert.
Inside Diameter
Note: The higher the orifice number the smaller the 
hole in the tip. For example, a number 52 orifice has 
a larger hole than a number 60 orifice.
“This conversion kit shall be installed by a qualified 
service agency in accordance with the manufacturer’s 
instructions and all applicable codes and requirements 
of the authority having jurisdiction.  If the information in 
these instructions is not followed exactly, a fire, explosion 
or production of carbon monoxide may result causing 
property damage, personal injury or loss of life.  The 
qualified service agency is responsible for the proper 
installation of this kit.  The installation is not proper and 
complete until the operation of the converted appliance 
is checked as specified in the owner instructions sup-
plied with the kit.”
Cer equipenent de conversion sera installe par une 
agence qualifiee de service conformement aux instruc-
tions du fabricant et toutes exigencies et codes appli-
cables de l’autorises avoir la jurisdiction.  Si l’information 
dans cette Instruction n’est pas suivie exactement, un 
feu, explosion ou production de protoxyde de carbone 
peut resulter le dommages causer de propriete, perte 
ou blessure personnelle de vie.  L’agence qualifiee de 
service est esponsable de l’installation proper de cet 
equipement.  L’installation n’est pas proper et complete 
jusqu’a  l’operation  de  l’appareil  converti  est  cheque 
suivant les criteres etablis dans les instructions de pro-
prietaire provisionnees avec l’equipement.
Burn Only the Fuel for Which the Heater is 
Equipped
This Conversion Kit Shall Be Installed By A 
Qualified Service Agency.
The ShadowLight XL Fireplace Insert will burn either 
natural gas or propane, but requires a change over 
kit for converting to natural gas. 
The  label  located  on  the  inner  stove  base  must  be 
marked for the type of fuel the unit will use at the time 
of installation.
Converting to Natural Gas
Caution: Before proceeding with the  conversion, 
the  gas  supply  must  be  shut  off  prior  to 
disconnecting the electrical power. 
LP  and Natural Gas Conversion Kits
Do  not  stike  glass  or  close  door  with  excessive 
force. Breakage of glass and/or damage to door 
may result.
14