Installation
Only For Qualified Installers
Remove three screws to change knob assembly. Install NG knob assembly in place of the LP assembly. Be 
sure screws are tight.
5
Place conversion sticker (provided in Kit) on the valve. This 
is to permanently mark the valve that it has been converted 
to  Natural  Gas. This  label  is  important  in  the  event  that 
the valve is ever removed and mixed in with other valves. 
Reassemble all components removed during the conversion 
process.
6
Mark  the  proper  box  on  the  fuel  label  with  a 
permanent  marker.  Note:  If  no  conversion  is 
made, the box for propane must still be marked.
7
Safety Label
Use soap and water and/or a gas detector to 
check for leaks before lighting the pilot.
8
When installation has been completed, verify the gas inlet 
and manifold pressures are within specifications. The safety 
label, located inside the bottom of the unit, will have the 
information  needed  to  verify  correct  operation. To  read 
the safety label, pull the label out away from the unit. Be 
sure to use the information for the type of gas that it will 
be using.
You must check the unit for any gas leaks using soapy 
water or an electronic style leak detector.
16