CLEANING AND 
MAINTENANCE
  WARNING:  Turn  off  heater 
and let cool before cleaning.
 CAUTION: You must keep con-
trol areas, burner and circulating 
air passageways of heater clean. 
Inspect  these  areas  of  heater 
before  each  use.  Have  heater 
inspected  yearly  by  a  qualified 
service person. Heater may need 
more  frequent  cleaning  due  to 
excessive  lint  from  carpeting, 
bedding material, pet hair, etc.
  WARNING:  Failure  to  keep 
the  primary  air  opening(s)  of 
the burner(s) clean may result in 
sooting and property damage.
ODS/PILOT AND BURNER
Use a vacuum cleaner, pressurized air or small, 
soft bristled brush to clean.
BURNER PILOT AIR INLET
The  primary  air  inlet  holes  allow  the  proper 
amount of air to mix with the gas. This provides a 
clean burning flame. Keep these holes clear of dust, 
dirt and lint. Clean these air inlet holes prior to each 
heating season. Blocked air holes will create soot. 
We recommend that you clean the unit every three 
months during operation and have heater inspected 
yearly by a qualified service person.
We  also  recommend  that  you  keep  the  burner 
tube and pilot assembly clean and free of dust and 
dirt. To clean these parts we recommend using 
compressed air no greater than 30 PSI (200 kPa). 
Your local computer store, hardware store or home 
center may carry compressed air in a can. You can 
use a vacuum cleaner in the blow position. If using 
compressed air in a can, please follow the direc-
tions on the can. If you don't follow directions on 
the can, you could damage the pilot assembly.
1.  Shut off the unit, including the pilot. Allow 
the unit to cool for at least thirty minutes.
2.  Inspect burner, pilot for dust and dirt.
3.  Blow air through the ports/slots and holes in 
the burner.
4.  Never insert objects into the pilot tube.
Clean the pilot assembly also. A yellow tip on the 
pilot flame indicates dust and dirt in the pilot as-
sembly. There is a small pilot air inlet about two 
inches from where the pilot flame comes out of 
the pilot assembly (see Figure 23). With the unit 
off, lightly blow air through the air inlet. You may 
blow through a drinking straw if compressed air 
is not available.
CABINET
Air Passageways
Use  a  vacuum  cleaner  or  pressurized  air  to 
clean.
Exterior
Use a soft cloth dampened with a mild soap and 
water mixture. Wipe the cabinet to remove dust.
BATTERIES
During long periods of time when the heater is 
not being used, take batteries out of receiver and 
ignitor. Remove exhausted batteries immediately. 
Do not mix old and new batteries.
SERVICE HINTS
When Gas Pressure Is Too Low
•  pilot will not stay lit
•  burner will have delayed ignition
•  heater will not produce specified heat
•  propane/LP gas supply may be low
You may feel your gas pressure is too low. If so, con-
tact your local natural or propane/LP gas supplier.
TECHNICAL SERVICE
You may have further questions about installation, 
operation or troubleshooting. If so, contact DESA 
Heating Productsʼ Technical Service Department 
at 1-866-672-6040. When calling please have your 
model and serial numbers of your heater ready.
You can also visit DESA Heating Productsʼ techni-
cal service web site at www.desatech.com.
Figure 23 - Pilot Air Inlet
Pilot Assembly
Pilot Air Inlet