TROUBLESHOOTING
Continued
POSSIBLE CAUSE
1. Pilot knob not fully pressed in
2. Pilot knob not pressed in long 
enough
3.  Equipment shutoff valve not 
fully open
4. Thermocouple  connection 
loose at control valve
5. Pilot flame not touching ther-
mocouple, which allows ther-
mocouple  to  cool,  causing 
pilot  flame  to  go  out.  This 
problem could be caused by 
one or both of the following:
  A) Low gas pressure
  B) Dirty or partially clogged 
ODS/pilot
6. Thermocouple damaged
7. Valve damaged
 1. Burner orifice(s) is clogged
2. Inlet gas pressure is too low
1. Manifold pressure is too low
2. Burner orifice(s) is clogged
1. Burner orifice(s) is clogged or 
damaged
2. Burner damaged
3. Gas regulator defective
1. Plaque damaged
2. Inlet gas pressure is too low
1. Residues from manufacturing 
processes
1. Metal expanding while heating 
or contracting while cooling
REMEDY 
1. Press in pilot knob fully
2.  After ODS/pilot lights, keep pi-
lot knob pressed in 30 seconds
3. Fully open equipment shutoff 
valve
4. Hand tighten until snug, then 
tighten 1/4 turn more
5. A)  Contact  local  natural  or 
propane/LP gas company
  B)  Clean  ODS/pilot  (see 
Cleaning  and  Maintenance
page 16) or replace ODS/pilot 
assembly 
6. Replace pilot assembly
7. Replace valve
1. Clean  burner  orifice(s)  (see 
Cleaning and Maintenance, page 
16) or replace burner orifice(s)
2. Contact local natural or pro-
pane/LP gas company
1. Contact local natural or pro-
pane/LP gas company
2. Clean  burner  orifice(s)  (see 
Cleaning and Maintenance, page 
16) or replace burner orifice(s)
1. Clean  burner  orifice(s)  (see 
Cleaning and Maintenance, page 
16) or replace burner orifice(s)
2. Replace burner
3. Replace gas regulator
1. Replace burner
2. Contact local natural or pro-
pane/LP gas company
1. Problem will stop after a few 
hours of operation
1. This is common with most heat-
ers. If noise is excessive, contact 
qualified service person
OBSERVED PROBLEM
ODS/pilot  lights  but  flame 
goes out when control knob is 
released
Burner(s)  does  not  light  after 
ODS/pilot is lit
Delayed ignition of burner(s)
Burner backfiring during com-
bustion
Burner plaque(s) does not glow
Slight  smoke  or  odor  during 
initial operation
Heater produces a clicking/tick-
ing noise just after burner is lit 
or shut off